Connection To The Chimney - LA NORDICA FIAMMETTA Instructions Pour L'installation, L'utilisation Et L'entretien

Poêles cheminées
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FIAMMETTA – GIORGIA – ASIA – FIORELLA – LUCY
2 m
1
m
CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98
Inclination of the
roof
α α α α
15°
30°
45°
60°
6.

CONNECTION TO THE CHIMNEY

For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the
fuel or for removing the ashes, while during the operation and the rest, the door of the hearth must remain closed.
The appliances with constructive system 2 must be connected to their own flue. The operating with open door is
allowed under supervision.
The stove is endowed with an upper exhaust pipe. The connection pipe to the flue must be the shortest possible,
right, tight and according to the current regulations.
The connection to the chimney must be performed with stable and strong pipes (we recommend a thickness of 2
mm). The pipe for smokes exhaust must be fixed hermetically to the chimney. The diameter inside the connection
7196601 – Rev.07 – EN
10 m
(1) The chimney cap must not show hindrances within 10 m from
walls, pitches and trees. Otherwise raise it of at least 1 m over the
hindrance.
The chimney cap must exceed the ridge of the roof of at least 1 m.
>A
H min.
α
Distance between the roof
ridge and the stack
A (m)
< 1.85 m
> 1.85 m
< 1.50 m
> 1.50 m
< 1.30 m
> 1.30 m
< 1.20 m
> 1.20 m
> _ A
(1)Ridge axis
(2)Roof
Minimum height of the stack
(measured from the outlet)
0.50 m above the roof ridge
1.00 m from the roof
0.50 m above the roof ridge
1.30 m from the roof
0.50 m above the roof ridge
2.00 m from the roof
0.50 m above the roof ridge
2.60 m from the roof
0,5 m
H (m)
Picture 6
Picture 7
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

AsiaGiorgiaFiorellaLucy

Table des Matières