Assembly Instructions – Natural Gas
Propane to Natural Gas Conversion
WARNING: This conversion shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the Authority Having Jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing
property damage, personal injury, or loss of life. The qualified service agency is responsible for the proper installation
of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as
specified in the manufacturer's instructions supplied with the kit. Appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff valve during any pressure testing of the piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
• This fire feature can be used with propane and natural gas. This fire feature is adjusted and shipped for use with propane
gas. To convert to natural gas use ONLY the natural gas orifice included with the kit.
CAUTION: Before converting the fire feature, ensure the gas
supply is shut off and the power cable is disconnected.
1. Adjust air shutter to a closed position (no light visible
through the shutter) by loosening the small screw on
the venturi/air mixer and rotating it to a closed position and
re-tightening screw (Ex. 5).
2. Loosen and remove the flare nut and propane orifice with
two wrenches (Ex. 5 & 6).
3. Locate the natural gas orifice and install securely in the same position as the removed
propane orifice.
4. Placing all markings provided in the kit in the appropriate location on the converted
appliance. Affix the conversion marking as close as possible to the existing rating plate.
5. Perform proper leak testing of the converted appliance prior to placing it into operation.
See "Checking for Leaks" section on page 12 of this manual. Natural gas fire features
are set up to operate on natural gas only, at a pressure of seven inches of water
column (7" WC). Check with your gas utility for local gas pressure. Natural gas input
rating is 60,000 BTU/hr (
6. After lighting, rotate the burner control knob counterclockwise to "LOW" setting.
Observe the flame and make sure all burner ports are lit. The flame height should be
no higher than 15-21 inches tall.
Installing the Batteries
• Locate the battery pack at the bottom of the flame control system. Remove back plate from
the battery pack and install 8 x AA batteries as shown (Ex. 7). Securely reinstall the back
plate, do not over tighten.
Connecting the Flame Control System
• Aquascape fire features ship with a 10 foot/3 m gas hose and electrical cable pre-attached
to the bottom of the burner system. Be sure to connect
and lay out all components before finalizing installation
(see pg. 9 for details).
• Connect the opposite end of the gas hose to the 3/8"
flare connection on the flame control system as shown
(Ex. 8). After making all connections, perform a leak test
as described on page 12 of this manual.
NOTE: Do not use pipe compound or Teflon PTFE tape
on flare gas connections.
• Connect the opposite end of the cable to the flame
control system as shown, fully inserting before hand-tightening the collar (Ex. 8).
aquascapeinc.com |
CAN (866) 766-3426 |
kW/h).
17.58
US (866) 877-6637
Venturi/Air
Mixer
Fire Feature
Air Shutter
Orifice
Flare Nut
Auto-Ignite Flame
Control System
Auto-Ignite
Power Cable
Rubber Gas Hose
Ex. 5
Ex. 6
x 8
x 8
Ex. 7
Ex. 8