Usage Precautions
Power supply precautions
If the unit is suddenly turned off during operation, data loss
may occur. To maintain data integrity, the use of an
uninterruptible power supply (UPS) is recommended.
To disconnect the power cord or turn off the breaker,
always press the On/Standby button on the unit to stop the
unit before proceeding.
Components with limited lifespan
The fan and battery are consumable parts that will need
periodic replacement.
When operating at room temperature, a normal
replacement cycle will be about 2 to 5 years.
However, this replacement cycle represents only a general
guideline and does not imply that the life expectancy of
these parts is guaranteed. For details on parts replacement,
contact your dealer.
Network precautions
Depending on the operating environment, unauthorized
third parties on the network may be able to access the
system. We strongly recommend configuring all of the
passwords for security purposes.
Configure all the passwords following the procedure on
page 16.
USB device precautions
The unit does not support UASP (USB Attached SCSI
Protocol).
18
Usage Precautions / Specifications
Specifications
General
Power requirement
100 V to 240 V AC
50/60 Hz
Power consumption
235 W
Standby power consumption
3 W or lower
Operating temperature
5 °C to 35 °C (41 °F to 95 °F)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Operating humidity
20% to 90% (relative humidity)
Storage humidity
5% to 80%
Mass
9.8 kg (21 lb. 9.7 oz.)
Dimensions
440 × 43.6 × 507 mm (17
20 in.) (width / height / depth)
3
440 (17
/
)
8
482 (19)
CPU
Processor
Intel Core i7-3770 (3.4 GHz)
Memory
8 GBytes
SO-DIMM (DDR3) (2)
Drive (m-SATA)
60 GBytes
Expansion bus PCIe Gen2 8Lane (30 W) (2)
Inputs/outputs
LAN
RJ-45 (2)
1000BASE-T, 100BASE-TX
USB (front panel/rear panel)
Super Speed USB (USB 3.0) Type A
(6, 2 on front and 4 on rear)
Front: Power delivery support (900 mA/
port)
3
3
/
× 1
/
×
8
4
Unit: mm (in.)
507 (20)
3
43.6 (1
/
)
4