geNeral safeTY iNformaTioN
eN
ATTENTION: It is prohibited to carry out any kind of assembly, repair or adjustment to the apparatus by unqualified staff, and if the necessary precautions haven't been taken and power
supply disconnected (including any back-up batteries), in order to avoid any possible accident or injury, . DASPI will not be responsible for any damage or injury to people, animals or
objects resulting from improper use of the apparatus or for use other than what is specified in this instruction booklet, and/or resulting from any modification carried out on this product and its
components. This control panel is not suitable for installation in an explosive atmosphere. Keep this manual with care, enclose it to the technical installation file and keep them in a suitable an
convenient place known by whoever is concerned, for future reference.
producT TYpe
The E-SOFT control panel has been designed to control one or two motors for swinging gates 230 Vac 50/60 Hz and it is equipped with an electronic clutch and adjustable slowing down feature.
DASPI accepts no responsibility for uses other than those intended for the E-SOFT control panel.
led Table
led
DESCRIPTION
dl1
Always off, it turns on with PED command
Always off, it turns on with START command
dl2
dl3
Always on, it turns off with STOP command
Always on, it turns off with FOTO command
dl4
In case LED indications do not match the table above, check connections and proper order of connected devices.
programmiNg T of The coNTrol paNel
Switching DIP-SWITCHES must always be carried out with control panel disconnected from the electricity mains
off
1
Double leaf gate
2
Lower slowing down speed
sW1
3
Final stroke disabled
4
Electro-lock release disabled
1
Maximum torque at motor start disabled
Slowing down feature enabled. Opening and closing travel are completed
2
with slowing down speed.
sW2
3
Residential feature disabled
4
"Close after passing through photocells" feature disabled.
adJusTmeNT of The TorQue
The torque adjustment must be carried out by qualified staff and is one of the most important stages for control panel installation, since it has been designed to reduce to the minimu the risk
of crushing. Make sure that leaves can be stopped at any time according to current regulations. Power supplied to the operators can be regulated from 50 to 100% adjusting POWER trimmer.
Turn the trimmer clockwise to increase output power and torque, and turn anti-clockwise to lower power and torque. Torque measurements must be carried out according to regulations. It is
mandatory to check from time to time the correct adjustment of POWER trimmer in order to guarantee that control panel work safely at all times.
pre program TesT
To be carried out with the gate leaves in half open position and only after having installed all the safety devices according to regulations.
Make sure connections to the motors are well made, taking into account that the first operation will be an opening.
Make sure that the first motor to open is motor M1 In case it's not the first to open, invert the connection cables of the two motors (terminals 14-15-16 with terminals 17-18-19).
Make sure that motor M1 move in opening: in case it closes, invert the connection to terminals 15-16.
Make sure that motor M2 move in opening: in case it closes, invert the connection to terminals 18-19.
programmiNg The coNTrol paNel
programming working time and slowing down for double swing gate.
1) With gate leaves in completely closed position, press seT button. LED dl10 begins flashing.
2) Press WorK button. motor M1 opens.
3) When motor M1 leaf is almost open, press WorK button to fix slowing down position in opening
4) When motor M1 leaf is completely open, wait for 3 seconds before pressing WorK button: the electric motor cuts off . Working time of motor M1 is now stored.
5) Press WorK button again. Timing of opening delay from leaf 1 and leaf 2 will start.
6) . Pressing again work button will stop the delay timing and motor M2 opens,
7) When motor M2 leaf is almost open, press WorK button to fix slowing down position in opening
8) When motor M2 leaf is completely open wait for 3 seconds before pressing WorK button: the electric motor cuts off. Working time of motor 2 is now stored,
9) Press WORK button. Motor M2 . closes
10) Wait delay time from leaf 2 and leaf 1 in closing, then press WorK button. Motor M1 will close.
After the leaves are closed, programming is completed and control panel will switch to working mode automatically.
N.b. When interruption of the programming occurs (photocells, stop) it is necessary to restart from point 2.
In order to programme by means of remote control button ( it must be previously stored ) , at point 1) above press Set and Work button at the same time (LED DL10 will flash) and continue from
point 2). Press remote control button where Work button is mentioned in the above procedure.
programmiNg WorKiNg Time aNd sloWiNg doWN for siNgle sWiNg gaTe (sW1 - dip 1 = oN)
1) With gate leaf in completely closed position, press seT button. LED DL10 begins flashing
2) Press WorK button. Motor M1 opens.
3) When leaf is almost open, press WorK button to fix slowing down position in opening.
4) ) When leaf is completely open, wait for 3 seconds before pressing WorK button: the electric motor cuts off . Working time is now stored.
5) Press WorK button, the motor closes.
After the gate is closed, programming is completed and control panel will switch to working mode automatically.
N.b. When interruption of programming occurs (photocells, stop) it is necessary to restart from the point 2.
led
DESCRIPTION
dl5
Always on, it turns off with t FOTOAP command
Always on, it turns off with SAFETY EDGE command
dl6
dl7
Always on, it turns off with OPEN command
Led signaling radio code storing and programming procedure
dl10
oN
Only the output of motor 1 (M1) is used.
Higher slowing down speed
Final stroke enabled (for electro-lock gates). Full power for 2 seconds at end
of closing.
Electro-lock release enabled. It reverse thrust for 2 seconds before the
openingin order to ease releasing of the electro-lock
Maximum torque at motor start enabled (2 seconds)
Slowing down feature disabled
Residential feature enabled: while the gate is opening START command is
ignored. When opening is completed, pressing the START button causes
immediate re-closing and no pausing time
"Close after passing through photocells" feature activated . When the gate is
open on passing and clearing the photocells gate gloses automatically.