IO-Link pre defi ned parameters
Index
Subindex (dec)
Access
Parameter name
0x0010 (16)
0
R
Vendor Name
0x0011 (17)
0
R
Vendor Text
0x0012 (18)
0
R
Device Name
0x0013 (19)
0
R
Product Id
0x0014 (20)
0
R
Device Text
0x0015 (21)
0
R
Serial Number
0x0018 (24)
0
R/W
Application
Specifi c Tag
5/5
Coding
Defi nition
Baumer Electric AG
String
String
www.baumer.com
String
<Product Key External>
(<Product Key Internal>)
String
Baumer Article Number
String
Sensor specifi c
String
<Production Order Nr>_<Serial Nr>
String
Default: Filled with ******,
as recommended by the IO-Link spec.
IO-Link Baumer specifi c parameters
Index
Subindex (dec)
Access
Parameter name
Local teach lock
0x0050 (80)
0
R/W
time
Response Delay
01
R/W
Filter
0x0060 (96)
Release Delay
02
R/W
Filter
0x0061 (97)
Minimum pulse
0
R/W
duration
3)
3)
Der Wert wird auf 5ms gerundet
The value is rounded to 5ms
Coding
Defi nition
0: Local teach never locked
1 ‒ 120: Local teach locked
after n minutes
Unit8
0xFF: Local teach always
locked
Default value: 5
0: fi lter OFF (default)
Uint16
5 ... 1000
3)
: Delay in ms in steps of
5ms
0: fi lter OFF (default)
Uint16
5 ... 1000
3)
: Delay in ms in steps of
5ms
0: pulse duration OFF (default)
3)
Uint16
5 ... 1000
: Minimum pulse in ms in
steps of 5ms
3)
La valeur est arrondie à 5 ms