Guidance And Manufacturer's Declaration - Electromagnetic Immunity - Eng3 NanoVi Eco Manuel

Table des Matières

Publicité

eng3
Voltage dips, short interruptions
and voltage variations on power
supply input lines
(Blackouts, brownouts, and fluctuations
of the power supply according to IEC )
IEC 61000-4-11
Power frequency
(50/60Hz)
magnetic field
IEC 61000-4-8
NOTE U
is the a.c. mains voltage prior to application of the test level.
T
The NanoVi is intended for use in the electromagnetic environment specified below. The customer or the user of the NanoVi should assure that it is used in
such an environment.
Immunity test
Conducted FR
IEC 61000-4-6
Radiated RF
Transient RF
IEC 61000-4-3
0 % UT; 0.5 cycle
At 0°, 45°, 90°, 135°,
180°, 225°, 270° and
315°
0 % UT; 1 cycle and 70
% UT; 25/30 cycles
Single phase: at 0°
0 % UT; 250/300 cycles
30 A/m

Guidance and manufacturer's declaration - electromagnetic immunity

lEC 60601 test
level
3 Vrms
3 V
150 kHz to 80 MHz
150 kHz to 80 MHz
6 Vrms in ISM bands be-
6 Vrms in ISM bands be-
tween 0.15 MHz and 80
tween 0.15 MHz and 80 MHz
MHz
80 % AM at 1 kHz
80 % AM at 1 kHz
10 V/m
3 V/m
80 MHz to 2,7 GHz
80 MHz to 2,7 GHz
80 % AM by 1 kHz
80 % AM by 1 kHz
0 % UT; 0.5 cycle
At 0°, 45°, 90°, 135°,
180°, 225°, 270° and
315°
0 % UT; 1 cycle and 70
% UT; 25/30 cycles
Single phase: at 0°
0 % UT; 250/300 cycles
30 A/m
Compliance level
Electromagnetic environment - guidance
Portable and mobile RF communications equipment should be
used no closer to any part of the NanoVi, including cables, that
the recommended separation distance calculated from the
equation applicable to the frequency of the transmitter.
Use of this equipment adjacent to or stacked with other equip-
ment should be avoided because it could result in improper op-
eration. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are normally.
�������� =
Recommended separation distance
�������� =
�������� =
10
Where P is the maximum output power rating of the transmitter
in watts (W) according to the transmitter manufacturer and d is
the recommended separation distance in meters (m).
26
Mains power quality should be that of a typical com-
mercial or hospital environment. If the user of the Na-
noVi requires continued operation during power
mains interruptions, it is
recommended that the NanoVi be powered from an
uninterruptible supply or a battery.
Power frequency magnetic fields should be at levels
characteristic of a typical commercial or hospital envi-
ronment.
√ ���� ����
3,5
3
√ ���� ����
3,5
10
80 MHz to 800 MHz
√ ���� ����
7
800 MHz to 2,5 GHz