Maintenance Intervals En - Binzel IROB P400 Mode D'emploi

Source de courant pour soudage robotisé
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9 Maintenance and cleaning
9.1 Maintenance intervals
NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
Observe the instructions given in EN 60974-4 Inspection and test during the operation of arc welding
equipment and the laws and guidelines valid in the respective country.
Check the following:
Daily
Check all cables, connecting hoses and
connections for damage, replace them if
necessary
General condition
Install the robot welding power source
maintaining a circumferential clearance of
50 cm to ensure optimum circulation of the
cooling air.
Tab. 10
Maintenance intervals
EN - 20
Monthly
Check all mobile parts and roll bearings for
correct functioning and replace them, if
necessary.
Quarterly
Both fans, replace them if necessary.