Omega 40500 Manuel D'utilisation page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
Important: Use only good grade hydraulic jack oil. Avoid
mixing different types of fluid and NEVER use brake
fluid, turbine oil, transmission fluid, motor oil or glycerin.
Improper fluid can cause premature failure of the jack
and the potential for sudden and immediate loss of load.
We recommend premium hydraulic jack oil.
Adding oil
1. With lifting arm fully lowered set jack in its upright,
level position. Locate and remove oil filler plug.
2. Fill with oil until ~3/16" above the inner cylinder as
seen from the oil filler hole. Reinstall oil filler plug.
Changing oil
For best performance and longest life, replace the
complete fluid supply at least once per year.
1. With lifting arm fully lowered, remove oil filler plug.
2. Lay the jack on its side and drain the fluid into a
suitable container.
Note. Dispose of hydraulic fluid in accordance with
local regulations.
3. Fill with oil until ~3/16" above the inner cylinder as
seen from the oil filler hole. Reinstall oil filler plug.
TROUBLESHOOTING
Symptom
Jack will not lift load
Jack will lift, but not maintain
pressure
Jack will not lower after unloading
Poor lift performance
Jack will not lift to full extension
All manuals and user guides at all-guides.com
Possible Causes
• Release valve not tightly closed
• Load is too heavy
• Release valve not tightly closed
• Hydraulic unit malfunction
• Reservoir overfilled
• Linkage binding
• Fluid level low
• Air trapped in system
• Fluid level low
5
Lubrication
A periodic coating of light lubricating oil to pivot points,
axles and hinges will help to prevent rust and assure that
wheels, casters and pump assemblies move freely.
Cleaning
Periodically check the pump piston and ram for signs
of rust or corrosion. Clean as needed and wipe with
an oily cloth.
Note: Never use sandpaper or abrasive material on
these surfaces!
Storage
When not in use, store the jack with lifting arm fully
lowered.
Corrective Action
• Ensure release valve tightly closed
• Consider higher capacity jack
• Ensure release valve tightly closed
• Discontinue use, contact your
local Omega Representative or
visit www.Omega.com to locate
your nearest store
• Ensure load is removed, then
drain fluid to proper level
• Clean and lubricate moving parts
• Ensure proper fluid level
• See Page 3 for bleeding/ venting
trapped air
• Ensure proper fluid level