Controller
1 – Error alarm -
2 – Thermal surcharge alarm
3 – Machine under voltage indicator
4 – Digital display (Welding current, Mecapulse, wire speed adjustment )
5 – V+ adjustment indicator
6 – V- adjustment indicator
7 – Welding current selected indicator
8 – Wire feed motor speed adjustment indicator
9 – Selector Mecapulse/Welding current/Wire speed
10 – Arc Air mode indicator
11 – Mecapulse mode indicator
12 - Spot welding time adjustment indicator
1 – Alarm –
2 – Alarm – thermal surcharge (
operation. The thermal switch is placed on the main transformer central coil.
3 – Machine under voltage – When lighted indicates that machine is under voltage.
4 – Digital display – Shows the selected parameter value (Mecapulse times and wire speed adjustment). During welding:
- the digital display indicates welding current value
- when the button is rotated the digital display shows the wire motor speed m/min, after this adjustment automatically
returns to welding current value.
5 – V+ Mecapulse – When selected allow adjust upper speed time.
6 - V- Mecapulse – When selected allow adjust lower speed time.
7 – I2 – Welding current – When selected welding current is showed on the digital display.
8 – Wire speed – When selected allows adjust, by means of the adjusting button, the wire speed between 0 and 18 m/min.
This parameter is continuous active; with machine running, select this function with key button 9 to adjust wire speed.
9 – Selector key button – Selects to adjust Mecapulse times and wire speed adjustment and to display welding current
reading.
MIG SELECT 300H/4R / 350H/4R / 400H/4R / 500H/4R / 650H/4R
Fig.6 -
or
or
(see errors description page on this user's guide)
) – When lighted indicates that thermal switch is activated by overload not allowing
Controller
14 – 4T (4 times) torch mode indicator
15 – Arcair/Spot/Mecapulse/2T/4T/ selector
16 – Digital display (welding voltage and time)
17 – Adjustable parameters selector
18 – Post-gas adjustment indicator
19 – Spot time adjustment indicator
20 – Burn-back time
21 - Up-slope time
22 - Welding voltage indicator
23 – Adjustment button
13 – 2T (2 times) torch mode indicator
7