Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WHAT'S IN THE BOX
•  LED FLOOD LIGHT FIXTURE
(INCLUDES TRUNNION MOUNT)
WHAT YOU'LL NEED
•  SCREWDRIVER / POWER DRILL
•  WIRE CUTTERS
•  FL3-SF (OPTIONAL SLIP FITTER MOUNT)
•  FL3-MA (OPTIONAL MOUNTING ARM)
•  FL3-RPA (OPTIONAL ROUND POLE ADAPTER)
•  WIRING SUPPLIES AS SPECIFIED BY
ELECTRICAL CODE
WARNING
To avoid electric shock:
Be certain electrical power is OFF before and during installa;on and maintenance.
• 
• 
Luminaire must be connected to a wiring system with an equipment-grounding conductor.
To avoid explosion:
Make sure the supply voltage is the same as the rated luminaire voltage.
• 
• 
Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
Keep lens ;ghtly closed when in opera;on.
• 
FL3 SERIES
MULTI-MOUNT
FLOOD LIGHTS
INSTALLATION INSTRUCTIONS
For use with:
FL3-1004T5-1-XX-ZZ | FL3-1004T3-1-XX-ZZ
FL3-1004T5-2-XX-ZZ | FL3-1004T3-2-XX-ZZ
FL3-1504T5-1-XX-ZZ | FL3-1504T3-1-XX-ZZ
FL3-1504T5-2-XX-ZZ | FL3-1504T3-2-XX-ZZ
FL3-2304T5-1-XX-ZZ | FL3-2304T3-1-XX-ZZ
FL3-2304T5-2-XX-ZZ | FL3-2304T3-2-XX-ZZ
FL3-3004T5-1-XX-ZZ | FL3-3004T3-1-XX-ZZ
FL3-3004T5-2-XX-ZZ | FL3-3004T3-2-XX-ZZ
FL3-4004T5-1-XX-ZZ | FL3-4004T3-1-XX-ZZ
FL3-4004T5-2-XX-ZZ | FL3-4004T3-2-XX-ZZ
IMPORTANT
Before assembling your fixture,
please make sure that you carefully
read through this instruc;on sheet.
Consider having your fixture installed
by a qualified licensed electrician.
This luminaire is suitable for use in
the following loca;ons: ambient
temperature of -40°F/-40°C~104°F/
40°C and wet loca;ons.
PREMISE LED Inc.
80-86 Carrier Drive
Toronto, ON Canada
M9W 5R1
PREMISELED.COM
1

Publicité

loading

Sommaire des Matières pour Premise FL3 Serie

  • Page 1 •  WIRE CUTTERS This luminaire is suitable for use in •  FL3-SF (OPTIONAL SLIP FITTER MOUNT) the following loca;ons: ambient •  FL3-MA (OPTIONAL MOUNTING ARM) temperature of -40°F/-40°C~104°F/ •  FL3-RPA (OPTIONAL ROUND POLE ADAPTER) 40°C and wet loca;ons. •  WIRING SUPPLIES AS SPECIFIED BY ELECTRICAL CODE WARNING To avoid electric shock: Be certain electrical power is OFF before and during installa;on and maintenance. •  •  Luminaire must be connected to a wiring system with an equipment-grounding conductor. PREMISE LED Inc. 80-86 Carrier Drive To avoid explosion: Toronto, ON Canada Make sure the supply voltage is the same as the rated luminaire voltage. •  •  Do not operate in ambient temperatures above those indicated on the luminaire nameplate. M9W 5R1 Keep lens ;ghtly closed when in opera;on. •  PREMISELED.COM...
  • Page 2 LUMINAIRE OVERVIEW FL3-SF Slip Fider Adachment (Op;onal) FL3-MA Moun;ng Arm Adachment (Op;onal Removable Trunnion Mount Adachment FL3-RPA (Included FL3 Mul;-Mount Flood Light Round Pole Adapter (Trunnion mount included) , must use (Op;onal with FL3-MA) All FL3 Mul;-Mount Flood Lights include a trunnion mount for direct moun;ng to surfaces. Op;onally, a Slip Fider or Moun;ng Arm adachment can be purchased to replace the included trunnion mount bracket. If a Moun;ng Arm is used, it can also be adached to a Round Pole Adapter to mount the flood light to a round pole (4”-6” diameter poles). HOW TO DIRECT MOUNT TO SURFACE For Trunnion Mount models: 1.  Use expansion bolts to secure the fixture on moun;ng surface. 2.  Keep enough length wires to ensure adjus;ng angle unhindered. 3.  Connect wires into wiring terminal; white wire to “Neutral” terminal, black wire to “Live” terminal, green wire to “Ground” terminal; and fix them by screws. For 208V, connect second live wire to...
  • Page 3 HOW TO MOUNT WITH A SLIPFITTER Using Slip Fider adachment (FL3-SF, op;onal): 1. Adjust the fixture orienta;on by turning the bolt. 2. Connect wires into wiring terminal; white wire to “Neutral” terminal, black wire to “Live” terminal, gr een wire to “Ground” terminal; and fix them by scr ews. For 208V, connect second live wire to white wire. 3. Mount the fixture using via the slip fider on a post of diameter 2.65”, then ;ghten with screws. 4. Restore the electricity and check the opera;on of y our new ligh;ng fixture. Note: The boBom hole on the slip fiBer is reserved for sensor installaHon. HOW TO INSTALL USING MOUNTING ARM Using Moun;ng Arm adachment (FL3-MA, op;onal): 1. Open the side cover from the side connec;on. 2. Connect wires into wiring terminal; white wire to “Neutral” terminal, black wire to “Live” terminal, green wire to “Ground” terminal; and fix them by screws. For 208V, connect second live wire to white wire.
  • Page 4 •  FL3-RPA (ADAPTATEUR À POTEAU ROND FACULTATIF) Ce luminaire est adéquat pour être •  LES FOURNITURES DE CÂBLAGE DOIVENT u;lisé dans les emplacements CORRESPONDRE À CE QU’EXIGE LE CODE DE suivants : les endroits humides et où L’ÉLECTRICITÉ la température ambiante se situe entre -40~+50 °C. AVERTISSEMENT Pour éviter les décharges électriques : Assurez-vous que l’électricité est COUPÉE avant et pendant l’installa;on ou l’entre;en. •  •  Le luminaire doit être connecté à un système de câblage muni d’un conducteur de mise à la terre de PREMISE LED Inc. l’appareillage. 82-86 Carrier Drive Pour éviter une explosion : Toronto, ON Canada Assurez-vous que la tension d’alimenta;on est la même que la tension nominale du luminaire. •  M9W 5R1 N’u;lisez pas ce luminaire à des températures ambiantes supérieures à celles indiquées sur la plaque •  PREMISELED.COM signalé;que du luminaire. •  Pendant le fonc;onnement, assurez-vous que le verre de protec;on est solidement fermé.
  • Page 5 APERÇU DU LUMINAIRE FL3-SF Adaptateur d’emboîtement (En op;on) FL3-MA Bras de montage (En op;on) Amovible Support de montage FL3-RPA par tourillons Adaptateur à poteau (compris) Projecteur à montage mul;ple rond (faculta;f, à FL3 u;liser avec le FL3-MA). (Support de montage par tourillons compris) Tous les projecteurs à montage mul;ple FL3 comprennent un support de montage par tourillons pour le montage direct aux surfaces. En op;on, il est aussi possible de faire l’achat d’un adaptateur d’emboîtement ou d’un bras de montage pour remplacer le support de montage par tourillons. Lorsqu’un bras de montage est u;lisé, il peut aussi se fixer à un adaptateur à poteau rond pour monter le projecteur à un poteau rond (poteaux de 4 à 6 po de diamètre). COMMENT RÉALISER UN MONTAGE DIRECT SUR UNE SURFACE Pour les modèles à support de montage par tourillons : 1.  U;lisez des boulons extensibles pour fixer le luminaire à la surface de montage.
  • Page 6 COMMENT MONTER UN ADAPTATEUR D’EMBOÎTEMENT Avec un adaptateur d’emboîtement (FL3-SF, en op;on) : 1. Ajustez l’orienta;on du luminaire en tournant l e boulon. 2. Branchez les fils dans la borne pour filsélec triques; fil blanc dans la borne « neutre », fil noir dans la borne « sous tension », fil vert dansl a borne de « masse »; et fixez-les avec des vis. 3. Assemblez le luminaire en u;lisant l’adaptateur d’emboîtement sur un poteau de 2,65 po de di amètre, puis serrez avec des vis. 4. Réac;vez l’électricité et vérifiez le fonc;onnement de votre nouveau luminaire. Remarque : Le trou inférieur de l’adaptateur d’emboîtement est réservé à l’installa;on d’un capteur. COMMENT INSTALLER À L ’AIDE D’UN BRAS DE MONTAGE À l’aide de la fixa;on du bras de montage (FL3- MA, faculta;f) : 1. Ouvrir le couvercle du raccord de côté. 2.

Ce manuel est également adapté pour:

Fl3-1004t5-1 serieFl3-1004t3-1 serieFl3-1004t5-2 serieFl3-1004t3-2 serieFl3-1504t5-1 serieFl3-1504t3-1 serie ... Afficher tout