Télécharger Imprimer la page
ABB Thomas & Betts Iberville CI54151-LF Feuille D'instructions
ABB Thomas & Betts Iberville CI54151-LF Feuille D'instructions

ABB Thomas & Betts Iberville CI54151-LF Feuille D'instructions

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

OCTAGONAL BOXES FOR CEILING FANS
Installation instructions
SUPPLIED WITH 2 #10-32 MACHINE SCREWS AND STAR WASHERS
MAXIMUM LOAD CAPACITY: 35 LBS (15.9 KG) FAN, TIGHTENED AT A RECOMMENDED TORQUE OF 35 LBF-IN (3.95 N-m)
BOX INSTALLATION
Determine exact location. Octagonal box ceiling fan must be mounted ush with ceiling surface and directly supported by building
structure (see gure). It must also be located to allow rotating blade to clear any object or other buildings structures. Blade should be at
least 7 feet from oor when fan is hung. Wherever possible, octagonal box should sit at against wooden joist and fastened by the
bottom with two (2) #12 x 1-1/2" wood screws.
FAN INSTALLATION
Proceed with fan installation, following manufacturer's installation instructions. Ensure power at main electrical power is turned o
before starting installation.
Note: When mounting fan's mounting bracket, be sure to use two (2) #10-32 machine screws and star washers supplied with the box.
Star washers will prevent screws from loosening due to vibration.
In accordance with CEC 2012 Edition: Rules 12-3010 (8) & (9)
12-3010 (8) Where a ceiling outlet box marked for fan support is installed, the outlet box shall be
(a) securely attached directly to the building structure, or
(b) attached to a bar hanger securely attached directly to the building structure.
12-3010 (9) A pendant ceiling fan and all possible accessories weighing 16 kg (35 lbs) or more shall be supported independently of the
outlet box.
Approved for ceiling fan installation. Ceiling
fan may be mounted horizontally or with up
to 30
inclination.
o
MADE IN CANADA
WARRANTY: Thomas & Betts sells this product with the understanding that the user will perform all necessary tests to determine the suitability of this product for the
user's intended application. Thomas & Betts warrants that this product will be free from defects in materials and workmanship for a period of two (2) years following the
date of purchase. Upon prompt noti cation of any warranted defect, Thomas & Betts will, at its option, repair or replace the defective product. Misuse, misapplication or
modi cation of Thomas & Betts products immediately voids all warranties.
Limitations and Exclusions: THE ABOVE WARRANTY IS THE SOLE WARRANTY CONCERNING THIS PRODUCT, AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE SPECIFICALLY
DISCLAIMED. LIABILITY FOR BREACH OF THE ABOVE WARRANTY IS LIMITED TO COST OF REPAIR OR REPLACEMENT OF THE PRODUCT AND UNDER NO CIRCUMSTANCES
WILL THOMAS & BETTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
© 2014 Thomas & Betts. All rights reserved.
Instruction sheet for
CI54151-LF AND CI54171-LF
RECOMMENDED INSTALLATION
2 X 4
Ceiling
Thomas & Betts Corporation, Memphis, Tennessee
Thomas & Betts, St-Jean-sur-Richelieu, Quebec
Joist
CI54151-LF or
CI54171-LF
www.tnb.ca
CTA01205 A

Publicité

loading

Sommaire des Matières pour ABB Thomas & Betts Iberville CI54151-LF

  • Page 1 Instruction sheet for OCTAGONAL BOXES FOR CEILING FANS CI54151-LF AND CI54171-LF RECOMMENDED INSTALLATION Joist 2 X 4 Installation instructions Ceiling CI54151-LF or CI54171-LF SUPPLIED WITH 2 #10-32 MACHINE SCREWS AND STAR WASHERS MAXIMUM LOAD CAPACITY: 35 LBS (15.9 KG) FAN, TIGHTENED AT A RECOMMENDED TORQUE OF 35 LBF-IN (3.95 N-m) BOX INSTALLATION Determine exact location.
  • Page 2 Feuille d’instruction pour BOÎTES OCTOGONALES POUR VENTILATEURS CI54151-LF ET CI54171-LF INSTALLATION RECOMMANDÉE Solive 2 X 4 CI54151-LF ou Plafond Instructions d’installation CI54171-LF FOURNIES AVEC 2 BOULONS ET RONDELLES DE BLOCAGE DENTELÉES (#10-32). CHARGE MAXIMALE: VENTILATEUR DE 35 LBS (15.9 KG), SERRÉ AU COUPLE RECOMMANDÉ DE 35 LBF-PO (3.95 N-m) INSTALLATION DE LA BOÎTE Déterminer la location exacte.

Ce manuel est également adapté pour:

Thomas & betts iberville ci54171-lf