en
4.2
Electrical data
Rated voltage
Operation voltage
range
Rated current (max)
Power consumption
(max)
5.
Approvals
(Approvals are valid for marked devices)
E189090
Rated
Voltage
115 V AC
UL, cUL
230 V AC
24 V AC
12 V DC
24 V DC
48 V DC
09/2022
12 – 48V DC
10 – 60 V DC
12 V DC 24 V DC 48 V DC
275 mA
120 mA
65 mA
3.3 W
2.9 W
3.1 W
Visual Signal Appliance - General Signaling Equipment - UEES, UEES7
Suitable for indoor and outdoor use.
Warning: Not to be used as a Visual Public Mode Alarm Notification Appliance.
According to CSA-C22.2 No. 205-M1983 clause 4.3.4 the connection is limited
to max. three leads.
Operating instructions PY L-S
24 V AC
50/ 60 Hz
21.6 – 26.4
V AC
120V DC
167 mA
25 mA
2,93 W
4 VA
Page 3 / 8
115 - 230 V AC
50/ 60 Hz
120V DC
90 – 265 V AC
108 -132V DC
115V AC
230V AC
51 mA
36 mA
5,9 VA
8.3 VA
086200015d