Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.2.3. "TIME" button

In the working state, this button is the timer button, which allows setting the
timer to 0-12 hours; in standby state, this button is the schedule power on
button, which allows setting the schedule power-on time to 12-0 hours.
Timer function:
a) Press the "TIME" button in the power-on state to make the digital tube
(88) and Led_h indicator display the status; the digital tube will turn on and
off in 0.5 seconds. At this moment, the TIME button can be used to set the
time to 0H - 1H - 2H - 3H - 4H - 5H - 6H - 7H - 8H - 9H - 10H - 11H - 12H - 0H -
1H - 2H...; the step size is 1 hour, and the prefix 0 is not displayed. When the
TIME button is pressed for more than 2 seconds, the corresponding timer
function changes rapidly in 0.2 seconds. When the change is stopped, the
corresponding setting time is displayed.
b) After setting the timer, the digital tube immediately displays the ambient
temperature and timer alternately if there is no button operation for 5
seconds or any button other than the timer button is pressed within 5
seconds.
c) If the value is set to 0, it means that the timer is not set. The digital tube
displays the ambient temperature immediately if there is no operation in 5
seconds or any other button is pressed within 5 seconds.
d) (Digital tube) normal display: If the timer is not set, the digital tube always
displays the current ambient temperature, the unit "°C/°F" lights up, and the
display range is (-9°C~40°C) (10°F~99 °F), (LO displays when the tempera-
tures is below -9°C/10°F, and HI displays when the temperatures is above
40°C/99°F). If the timer is set, the ambient temperature is displayed for 5
seconds and then the remaining time is displayed for 5 seconds alternately.
Schedule power-on function:
a) Press the "TIME" button in the standby state to make the digital tube (88)
and Led_h indicator display the status; the digital tube will turn on and off in
0.5 seconds. At this moment, the TIME button can be used to set the time to
12H-11H-10H-9H- 8H-7H-6H-5H- 4H-3H-2H-1H-0H-12H-11H-10H...; the step
size is 1 hour, and the prefix 0 is not displayed. When the TIME button is
pressed for more than 3 seconds, the schedule power-on is turned off.
b) If the schedule time is set to 0, it means that schedule power on is turned
off, and the system will enter standby state if there is no operation in 5
seconds.
09

Publicité

Table des Matières
loading

Table des Matières