First Use; Important Safety Instructions - Spectro-UV Spectroline Edge 13 Manuel D'utilisation

Masquer les pouces Voir aussi pour Spectroline Edge 13:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EDG-13T KEY FEATURES:
• Nominal steady-state intensity of 6,500 µW/cm
• Large coverage area of 17.5 inches x 16 inches with a minimum
UV-A intensity of 1,000 µW/cm
• Less than 1.0 foot-candle (11 lux) visible light emission.
• Long-lasting UV-A Lenses.
• Cool running, fanless design.
• Multiple units can be ganged together, utilizing a single power source.
• Adjustable mounting bracket.
• IP65 Rated: The EDGE™ 13 Series lamps are protected from total
dust ingress and from low pressure jets of water (from all directions).
For more details, consult EN 60529 (British BS EN 60529:1992,
European IEC 60509:1989).
• The EDGE™ 13 is CE, CCC, RoHS, and WEEE compliant.
Meets EN ISO 3059 standards for non-destructive testing.

FIRST USE

• The EDGE™ 13 UV-A LED flood lamp is shipped factory set at the
specified intensity for optimal performance during inspections.
• Carefully unpack and inspect the lamp for possible damage during
shipment. If any damage is noted, immediately notify the carrier and
supplier before attempting to use the lamp.
• Make tests in a darkened area for best fluorescent response.
• Prior to plugging the unit into a grounded receptacle, ensure that
the power switch is in the OFF position. The EDG-13T lamps have a
two-position rocker switch (O = off and I = on).
• Push the power switch to the ON position. Instant-on operation ensures
that each of the UV-A LEDs reaches full intensity very quickly. Check to
see if the unit is operating optimally.
UV emitted from this product. Avoid eye and skin exposure to unshielded products.
FOR PROFESSIONAL EXAMINATION USE ONLY
at 15 inches (38cm).
2
.
2
WARNING
2

IMPORTANT SAFETY INSTRUCTIONS

The EDGE™ 13 Series UV-A LED flood lamps must be used with a properly grounded
outlet. Please read the instructions in this manual carefully before using the unit.
Never use the equipment in any manner not specified in these instructions.
The lamp is completely safe when used as directed (see MOUNTING INSTRUCTIONS
FOR
SAFE
OPERATION).
Spectroline
UV-absorbing protective eye and facewear. See REPLACEMENT PARTS
®
AND ACCESSORIES for model numbers. The available eye and facewear also
improves the contrast between the fluorescent area and the background.
The operator should stand away from the UV beam and not in a direct line of
sight. NOTE: No UV light should be seen on clothing or body parts. UV reflection
on clothing means the operator must move outside of the UV beam.
For maximum personal safety, we recommend using either the Spectroline
80 face shield, UVG-50 goggles or RP-UVS-30 spectacles.
NOTE: Be sure to use genuine EDGE™ 13 replacement parts. Using another
manufacturer's replacement parts could affect product performance and will void
the lamp warranty.
NOTE: Should the unit's internal temperature become too hot, the unit will
automatically shut down to avoid internal damage or deter use operating outside
of compliance (EDG-13T ONLY). In this event, allow time for the unit to cool.
The unit will power back on when within a safe operating temperature.
MOUNTING INSTRUCTIONS FOR SAFE OPERATION
Secure two eyebolts to the mounting bracket. Attach one metal chain link to each of
the eyebolts (not supplied). You may also affix the unit to any location utilizing the
mounting bracket and bolts. Assure the anchor you are utilizing is secure and can
safely hold the weight of the unit.
We
recommend
®
Mounting Bracket
Adjustment Bolt
3
using
UVF-

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Edg-13t

Table des Matières