WIDTH
MODEL
IN. (MM)
LCB15RMPF/
15 (381)
LCB15LMPF
LCB24RMPF/
24 (625)
LCB24LMPF
LCB36RMPF/
36 (930)
LCB36LMPF
LCB48RMPF/
48 (1234)
LCB48LMPF
NOTE: Gas inlet connection is 3/4" NPT.
6
OM-LCB
Specifications and Dimensions
DEPTH
HEIGHT
IN. (MM)
IN. (MM)
29 (740)
19 (480)
29 (740)
19 (480)
29 (740)
19 (480)
29 (740)
19 (480)
The appliance and its individual shutoff valve (to be supplied by user) must be
disconnected from the gas supply piping system during any pressure testing of that
system at test pressures in excess of ½ psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or greater than ½ psi (3.45 kPa).
:
# OF
BTU/BURNER
BURNERS
NAT/LP
1
40,000/40,000
2
40,000/40,000
3
40,000/40,000
4
40,000/40,000
Gas Pressure
TO AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH,
A FACTORY AUTHORIZED SERVICE AGENT SHOULD HANDLE ALL
MAINTENANCE AND REPAIR. BEFORE DOING ANY MAINTENANCE
OR REPAIR, CONTACT LOLO.
W.C.-IN.
TOTAL BTU/Hr / Kw
NAT/LP
40,000 / 11.7
6/10
80,000 / 23.5
6/10
120,000 / 35.16
6/10
160,000 / 46.9
6/10