WARNING
Do not adjust the low set-point higher than the high limit
thermostat.
Do not adjust the low set-point higher than the high temperature
set-point connected to the indicator light.
4.
Replace the metal plate and secure with two screws.
CONNECTING HEATER TO AC POWER
1.
The drum heater is designed to work at a specific voltage. Refer to the lead wire label or
stamp located on the heater for rated voltage and wattage.
Failure to operate the drum heater at its rated voltage could
WARNING
cause damage to the heater, surface being heated or contents of
drum.
All electrical connections must be made by qualified personnel
and in accordance with all local codes and regulations.
Properly sized circuit breakers must be used.
The end-user is responsible for providing suitable electrical
protection device. It is highly recommended that a ground fault
circuit breaker be used.
DHCH, DHCS, DPCH, DPCS and ECONO series
2.
The power cable consists of three color-coded conductors: black, white and green. The
black wire should be connected to Line 1. The white wire should be connected to Line 2.
The green wire should be connected to earth ground. The power connections must be
adequately rated to electrically support the voltage and amperage of the heater. The
identification label located on the power cord displays voltage and amperage requirements.
Follow all local electrical codes for proper electrical connections.
DHCX series
2.
Connect the hazardous location approved plug to power source only after all steps listed
above are complete.
DHNH, DHNS and DHNX series
2.
Refer to external temperature controller instructions for power installation instructions.
®
© BriskHeat
Corporation. All rights reserved.
Silicone Rubber Band Drum / Pail Heaters
7
TROUBLESHOOTING GUIDE
Please read this guide prior to contacting BriskHeat
commonly asked questions. If you are unable to identify the problem or need additional
assistance, please contact your local distributor/ representative or us at 1-800-848-7673,
614-294-3376, or bhtsales1@briskheat.com.
PROBLEM
SOLUTION(S)
Does not heat
Verify heater is connected to proper voltage. The identification label
located on the power cord displays the heater's voltage requirement.
Using an ohm meter, check to see if there is a resistance
reading (not an open circuit) in the heater.
Circuit breaker is
Validate that the circuit breaker is capable of handling the amp
tripping
requirement of heater. The identification label located on the power
cord displays the heater's amperage requirement.
Examine heater and cord for any damage.
Does not fit
Confirm that the heater provided was designed to fit around your
specified drum.
If the heater was designed for the specified drum, please call
1-800-848-7673 or 614-294-3376 for further assistance.
Something has lightly
Apply any general household cleaner, that does not contain any
spilled on exterior or
silicone rubber dissolving type ingredients, with a clean cloth fabric.
interior of heater
WARRANTY INFORMATION
BriskHeat warrants to the original purchaser of this product for the period of eighteen (18) months
from date of shipment or twelve (12) months from date of installation, whichever comes
first. BriskHeat's obligation and the exclusive remedy under this warranty shall be limited to the
repair or replacement, at BriskHeat's option, of any parts of the product which may prove
defective under prescribed use and service following BriskHeat's examination, is determined by
BriskHeat to be defective. The complete details of the warranty can be found online at
www.briskheat.com or by contacting us at 1-800-848-7673 (toll free, U.S. / Canada) or
1-614-294-3376 (Worldwide).
4800 Hilton Corporate Dr. Columbus, OH 43232
Toll Free: 800-848-7673
Phone: 614-294-3376
Fax: 614-294-3807
Email: bhtsales1@briskheat.com
®
© BriskHeat
Corporation. All rights reserved.
Silicone Rubber Band Drum / Pail Heaters
®