Nom du signal
RCPSettings.RegioControllerState-
BypassTimeZone2
RCPSettings.
RegioVAVOutputMinLimitOffZone2
RCPSettings.
RegioVAVOutputMinLimitUnoZone2
RCPSettings.RegioVAVOutputMin-
LimitStandbyZone2
RCPSettings.
RegioVAVOutputMinLimitOccZone2
RCPSettings.
RegioVAVOutputMaxLimitZone2
RCPSettings.RegioSupplyAirTem-
pLimCascadeFactorZone2
RCPSettings.RegioSupplyAirTem-
pLimHeatMinLimitZone2
RCPSettings.RegioSupplyAirTem-
pLimHeatMaxLimitZone2
RCPSettings.RegioSupplyAirTem-
pLimCoolMinLimitZone2
RCPSettings.RegioSupplyAirTem-
pLimCoolMaxLimitZone2
RCPSettings.RegioSupplyAirTem-
pLimFrostProtSetPointZone2
RCPSettings.
RegioCO2PBandZone2
RCPSettings.RegioCO2ITimeZone2 RegioCO2ITimeZone2
RCPSettings.
RegioCO2SetpointZone2
RCPSettings.
RegioFanStopTimeZone2
RCPSettings.
RegioCVHeatExerciseDay
RCPSettings.
RegioCVCoolExerciseDay
RCPSettings.
RegioCVHeatExerciseHour
RCPSettings.
RegioCVCoolExerciseHour
RCPSettings.
RegioHeatExerciseTime
RCPSettings.
RegioCoolExerciseTime
RCPSettings.
RegioCVHeatExerciseDayZone2
RCPSettings.
RegioCVCoolExerciseDayZone2
RCPSettings.
RegioCVHeatExerciseHourZone2
RCPSettings.
RegioCVCoolExerciseHourZone2
Regio
Ardo
manuel, Rev. C
Nom d'objet
Nº d'ins-
tance
30043
RegioControllerStateBy-
passTimeZone2
RegioVAVOutputMinLimi-
30044
tOffZone2
RegioVAVOutputMinLimi-
30045
tUnoZone2
30046
RegioVAVOutputMinLi-
mitStandbyZone2
RegioVAVOutputMinLimi-
30047
tOccZone2
RegioVAVOutputMaxLimi-
30048
tZone2
RegioSupplyAirTempLim-
30049
CascadeFactorZone2
RegioSupplyAirTempLim-
30050
HeatMinLimitZone2
RegioSupplyAirTempLim-
30051
HeatMaxLimitZone2
30052
RegioSupplyAirTempLim-
CoolMinLimitZone2
RegioSupplyAirTempLim-
30053
CoolMaxLimitZone2
RegioSupplyAirTempLim-
30054
FrostProtSetPointZone2
RegioCO2PBandZone2
30055
30056
RegioCO2SetpointZone2
30057
RegioFanStopTimeZone2 30058
RegioCVHeatExerciseDay 30062
RegioCVCoolExerciseDay 30063
RegioCVHeatExercise-
30064
Hour
RegioCVCoolExercise-
30065
Hour
RegioHeatExerciseTime
30066
RegioCoolExerciseTime
30067
RegioCVHeatExercise-
30068
DayZone2
RegioCVCoolExercise-
30069
DayZone2
30070
RegioCVHeatExercise-
HourZone2
RegioCVCoolExercise-
30071
HourZone2
Liste de signaux BACnet
Acces-
Description
sible en
écriture
OUI
Durée du mode By-pass (Min) Zone2
OUI
Limite Min Sortie VAV, mode Arrêt Zone2
OUI
Limite Min Sortie VAV, mode Eco Zone2
OUI
Limite Min Sortie VAV, mode Inoccupé
Zone2
OUI
Limite Min Sortie VAV, mode Confort ou By-
pass Zone2
OUI
Limite max pour sortie VAV Zone2
OUI
Facteur de cascade pour la cascade PID
Zone2
OUI
Consigne min pour la cascade PID en mode
Chauffage Zone2
OUI
Consigne max pour la cascade PID en
mode Chauffage Zone2
OUI
Consigne min pour la cascade PID en mode
Refroidissement Zone2
OUI
Consigne max pour la cascade PID en
mode Refroidissement Zone2
OUI
Température Soufflage Température Protec-
tion antigel Zone2
OUI
PID CO2 Bande P Zone2
OUI
PID CO2 Temps I Zone2
OUI
Consigne CO2 du régulateur PI en PPM
Zone2
OUI
Temps (sec) du délai d'arrêt ventilateur en
Postventilation
OUI
Jour de l'exercice vanne chauffage et vanne
chauffage/refroidissement, 1=Jamais, 2-8=
lun-dim, 9=tous les jours
OUI
Jour de l'exercice vanne refroidissement
OUI
Heure de l'exercice vanne chauffage et
vanne chauffage/refroidissement
OUI
Heure de l'exercice vanne refroidissement
OUI
Temps en secondes pour dégommer les
vannes de chauffage
OUI
Temps en secondes pour dégommer les
vannes de refroidissement
OUI
Jour de l'exercice vanne chauffage Zone2,
1=Jamais, 2-8=lun-dim, 9=tous les jours
OUI
Jour de l'exercice vanne refroidissement
Zone2
OUI
Heure de l'exercice vanne chauffage Zone2
OUI
Heure de l'exercice vanne refroidissement
Zone2