Programmation

3.1

Exiting time regulation

The exiting time allows the system user to leave the protected zones after the system
enabling. During this time a possible activation of the sensors of the all protection zones
doesn't activate alarms.
This timing is adjustable from 5 to 75 seconds by the trimmer situated inside of the central
unit, near the terminal boards.
The exiting time is signalled by the blinking of the green LED "EXIT" situated on the front
panel of the central unit.
3.2

Entering time regulation

The entering time allows the system user to access the protected environments and reach
the central unit to disable the system. During this time, a possible activation of the sensors
installed on the zone 1 doesn't activate an alarm cycle.
This timing is adjustable from 5 to 90 seconds by the trimmer situated inside of the central
unit, near the terminal boards.
The exiting time is signalled by the blinking of the yellow LED "Alarm" situated on the front
panel of the central unit.
If an electronic key or any command system is installed externally to the protected
environments it's advisable to adjust to minimum this timing.
3.3

Alarm time regulation

The alarm time is adjustable from 180 seconds to 10 minutes by the trimmer situated
inside of the central unit, near the terminal boards.
Entering time
Programmation
Exiting time
Alarm time