PROTEC3 - User's manual
1.3
Technical features
Protection zones immediate zone
!
Protection zones delayed zone
!
Protection zones for antisabotage "24h"
!
Power supply voltage
!
Service output voltage
!
Normal current consumption
!
Max current consumption
!
Max current consumption (only central unit)
!
Max current supplied by power supplier
!
Max current supplied on sirens output
!
Max current supplied on service output
!
Power supplier / battery charger
!
Buffer battery
!
Adjustable alarm duration
!
Box protection level
!
Transformer primary fuse
!
Transformer secondary fuse
!
Fuse on sirens output
!
Fuse on service output voltage
!
Adjustable exit timing
!
Adjustable entrance timing
!
External box
!
Operating temperature
!
Safety degree
!
Ambiental class
!
Dimensions (W)
!
Dimensions (H)
!
Dimensions (D)
!
Weight
!
Insulation class:
!
Prestation level:
!
Approved directives CEI EN 50131-1
!
20
1
1
1
230V~ ±5% 50Hz
12Vdc ±10%
40mA
50mA
35mA
1A
3A (with battery connected)
440mA
included
12V 7,5Ah (not included)
180 ÷ 600sec.
IP30
250mA L 250V type F
1A type F
3,15A L 250V type F
1A type F
4 ÷ 75sec.
4 ÷ 75sec.
ABS
+5°C ÷ +40°C
1
2
280mm
230mm
96mm
2 Kg
1°
security