Dimensions in mm

7.4 Electrical connection

WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed
near this symbol. Covers bearing this sign
may only be removed by a certifi ed skilled
electrician.
The electrical connection must be carried out by a
qualifi ed electrician who is authorised to carry out such
work!
Statutory regulations and the connection specifi cations
issued by the local power supply company must be
strictly observed.
When connecting the appliance it must be ensured that
there is a device which makes it possible to universally
disconnect it from the mains with a contact opening
width of at least 3mm. Line-protecting switches, fuses
or contactors are suitable cut-out devices. When
connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
The earth wire must be suffi ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
Any superfl uous cable must be removed from the
installation area beneath the appliance.
Make sure that the local mains voltage is the same as
the voltage on the rating label.
Full protection against accidental contact must be
ensured on installation.
Attention: Incorrect connection may result in the power
electronics unit being destroyed.
The appliance is only authorised for permanent
connection. It may not be connected with a shock-proof
plug.
Instructions for assembly
Power supply
Mains voltage: 380-415V 3N~, 50/60Hz
Component rated voltage: 220-240V
No mains cable present in the factory
To connect the appliance, unscrew the cover of the
connection socket on the underside of the appliance
in order to be able to access the terminal. After
connecting the appliance, replace the cover and secure
the connection cable with the strain relief clamp.
The connection cable must be at least H05 RR-F.
Electrical connections: 6-pole connection
* This type of electrical connection is not permitted by the SEV (Swiss Association of
Electrical Engineers) in Switzerland.