WPS / WPF - LED
INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious
injury or death. Only qualified electricians should install this fixture and the installation MUST conform to the Canadian
Electrical Code Part I and all local codes and ordinances. Ensure that only proper tools, materials, and equipment are used to
complete the installation.
SAFETY
Proper grounding is required to ensure personal safety.
Fixture should be mounted in locations where unauthorized personnel will not readily subject it to tampering.
Do not use this equipment for anything other than its intended purpose.
Servicing this equipment should be performed by qualified service personnel.
Save these instructions.
MIN 90 °C SUPPLY CONDUCTOR
INSTALLATION
1) Open the fixture by loosening the two screws on the side and swing open
the lens assembly. Be sure to disconnect connection terminal.
2) Prepare the back box for mounting by attaching gasket to the back and
drilling the appropriate holes.
3) Mount Wall Pack at desired location. Ensure that the top, both sides and
the mounting holes that are touching the wall are sealed with silicone.
4) Remove required conduit entry plug and use appropriate waterproof
connection to bring wiring into the Wall Pack. Make appropriate wiring
connections as per the wiring diagram.
5) Reconnect the connection terminals, close the lens assembly and secure
the two side screws.
RAB Design Lighting inc.
READ, UNDERSTAND
before installing the equipment.
April 2021
FOLLOW
, and
these instructions
Page 1 of 2

Publicité

loading

Sommaire des Matières pour RAB Design WPS-LED

  • Page 1 Wall Pack. Make appropriate wiring connections as per the wiring diagram. 5) Reconnect the connection terminals, close the lens assembly and secure the two side screws. RAB Design Lighting inc. April 2021 Page 1 of 2...
  • Page 2 Connect fixture WHITE wire to power supply NEUTRAL wire. • Connect fixture BLACK wire to power supply LINE wire • The fixture includes 0-10V dimming functionality, connect GREY and VIOLET wires to a 0-10V dimming controller (optional). RAB Design Lighting inc. April 2021 Page 2 of 2...
  • Page 3 5) Branchez les bornes de connexion, fermez l‘ensemble de la lentille et serez les deux vis. COMMUTATEURS SÉLECTIONNABLES CCT & LUMEN RAB Design Lighting inc. April 2021 Page 1 de 2...
  • Page 4 Branchez le fil NOIR du luminaire au fil de LIGNE de l'alimentation. • Le luminaire inclut une fonction d’intensité réglable de 0-10V, branchez les fils GRIS et VIOLET à un contrôleur de 0-10V (optionnel). RAB Design Lighting inc. April 2021 Page 2 de 2...

Ce manuel est également adapté pour:

Wpf-led