order to ensure proper device operation.
• If the environment in which the product is installed also houses a fuel-operating
device (water heater, methane stove etc., that is not a "sealed chamber" type), it
is essential to ensure adequate air intake, to ensure good combustion and proper
equipment operation.
• Install the product so that the impeller is not accessible from the air outlet side as
verified by contact with the Test Finger (test probe "B" of the norm EN61032) in
compliance with the current safety regulations.
INtroductIoN
QIN is an axial fan designed to ensure air extraction in small/medium-sized rooms such
as bathrooms, toilets and kitchens.
Suitable for air discharge directly to the outside or in the presence of short linear duct
(less than 1.5m). For in-line installation, horizontal or vertical (fig. 1).
techNIcal sPecIFIcatIoNs
• Material: High quality, impact and UV-resistant ABS colour RAL 9010.
• High efficiency aerodynamic fan with "winglet" blades to optimise quietness and
efficiency.
• Single phase induction motor with integral thermal protection.
• Motor mounted on high quality sleeve bearings.
• BB version (on request): motor mounted on ball bearings that guarantee a longer
product life cycle (30,000h) and suitable for cold climates.
• The fan is double insulated: no earth connection is required.
• Suitable for continuous or intermittent operation.
• IPX4 degree of protection.
• Power supply 220V to 240V~ 50/60Hz.
VersIoNs
staNdard
The fan is operated using a separate ON/OFF switch or via a light switch (fig. 7A).
WIth tIMer (over-run)
The fan is provided with a timer circuit which is adjustable from aprox. 1 minute to 25
minutes via trimmer (fig. 8B).
Operation: connected according to the diagram in fig. 7B, after the light is switched on,
the fan activates with a delay of max 1.5 seconds. After the light is switched off, the fan
continues to function for a pre-set period of time.
staNdard coNForMItY
2014/35/EC Low Voltage Directive (LVD)
2014/30/EC Electromagnetic Compatibility (EMC),
in conformity with the following standards:
Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2.
Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2(2015); EN 61000-3-
2(2014); EN 61000-3-3(2013).
5