English
Do not use this machine if tired, ill or if under the
effects of medicines, alcohol or drugs. The lack of rest
and fatigue can cause accidents and damages.
Do not use this machine at night, with fog or with
reduced visibility that does not allow you to clearly see
the working area.
Always be alert that the machine has no loose parts.
If you detect any loose parts, stop the machine
immediately and check the machine carefully. If you
detect any problems, stop the machine and take to
your nearest service dealer. Never carry on working
with the machine.
6.1. START AND STOPPAGE
The machine starts and stops automatically
depending on the position of the buoy once the
machine has been connected to the mains. This
machine has no manual switch.
6.2. CONNEXION TO THE MAINS
It is obligatory to connect the machine to a mains
switch protected by a residual differential equal to or
less than 30mA. Electricity tension should be 230v,
frequency 50Hz and have a magnet and thermal
switch between 10A-16A.
When using a cable extension, make sure that its
minimum section is 1.5 mm
metres, always unrolled and adequate for outdoor use.
The use of the cable extension adequate for outdoor
use, reduces the risk of electric shock.
Place the cable extension in such a way that it does
not touch the water and that it will not fall into the
water when the pump starts working. The cable
extension must always be well away from the water
and dry.
2
and no longer than 25
All electrical connexions should be outside of the
water, at a safe distance from the pump and water
conducts and protected from possible humidity.
Connect the pump to the mains. The machine should
work.
6.3. CHECKING POINTS AFTER START UP
Check that water comes out the impulsion hose
after a few seconds, that the noise of the machine is
normal and that it does not vibrate. If you detect any
anomaly, stop the machine immediately, check the
hose installation and the connexions to the mains.
If necessary, take the machine to your nearest after
sales dealer for repair.
Never carry on using the machine.
This pump comes with a self pumping system. When
the pump is submerged and started, this system
expels all the air through the ventilation orifice. If the
water level is below this orifice, some water might also
come out through the orifice. This is normal.
6.4. RECOMMENDATIONS
Do not use this pump with mud, sandy water,
excessively dirty and murky water or water with high
levels of impurities and/or filaments. These elements
could cause the blockage of the pump as well as
wearing the machine a lot quicker.
The pump will lower its water outflow the higher the
impulsion hose is. Always try and lower as much as
possible. Check the graph of outflow/height in point
4.3.
Do not leave the pump in the workplace after finishing
your task as it could get stuck in the mud once the
water has been cleared.
24/88