INSTALLATION INSTRUCTION
Connecting to a waste disposal unit with an air gap
MAKE THE CONNECTION UPLINE FROM THE SIPHON OF THE
DRAIN LINE AND AT LEAST 400 mm (15-3/4") ABOVE THE FLOOR
ON WHICH THE DISHWASHER WILL BE INSTALLED.
1.
Remove the cover of the waste disposal unit (ref. A fi g. 5-11).
2.
Connect the dishwasher drain hose (ref. B fi g. 5-11) to the air gap (ref. C
fi g. 5-11) using the wide spring clamp (ref. D fi g. 5-11); if necessary, cut the
end of the dishwasher drain hose (ref. E fi g. 5-12) (do not cut the corrugated
section). If the drain hose has been cut, use a 38 to 50 mm (1-1/2 to 2")
screw clamp*.
3.
To connect the air gap (ref. C fi g. 5-11) to the waste disposal unit inlet (ref. F
fi g. 5-11), use a rubber union* (ref. G fi g. 5-11) with spring or screw clamps*
(ref. H fi g. 5-11).
* Available from any plumbing stockist