Electrical connection (fig. 4a)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains supply;
- an all pole circuit breaker which leaves at least 3 mm between the contacts has been installed
between the device and the mains;
- the high voltage 230V wires pass through the holes marked "A" and are routed separately
from the low voltage wires which pass through the holes marked "B";
- the wires are fastened down using a cable clamp;
- once the wiring is complete the holes through which the wires have passed have been sealed
using silicon;
- the holes which are not used are blocked by inserting the caps "C".
Terminal board connections (fig. 5)
Caution: only low voltage circuits may be wired to the external circuit binding posts 7...14.
1-2
Power supply 230 Vac 50-60 Hz
3-4
Earth connection
230 Vac 2000 W output
5-6
7-8-9 Auxilliary output (NC-NA-C contact)
10
Switching input (N.O. contact). When this contact is open the output is inactive
11
Sequential button input "TD" (N.A. contact)
12
Common for all inputs
13
Antenna ground
14
Antenna pole