Cabinet Installation; Anti-Tip Brackets - hestan GRS_24 Manuel D'installation

Masquer les pouces Voir aussi pour GRS_24:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CABINET INSTALLATION

DANGER
the refrigerant tubing or increasing the risk of a leak.
EN
CASTER KIT (OPTIONAL)
CASTER KIT (OPTIONAL)
A Caster Kit (AGCK24) is available for Hestan undercounter refrigeration models. Refer to the
instructions supplied with the caster kit for proper installation.
Note: Installation of the kit adds 3.75" [9.5 cm] to overall height of the unit.

ANTI-TIP BRACKETS

ANTI-TIP BRACKETS
Unit may tip forward if loaded racks/shelves are all pulled out at the same time. To prevent tipping,
and to provide stable installation, the unit must be secured in place with the anti-tip brackets
supplied with the unit. The anti-tip brackets, when properly installed, should secure the rear legs/
glides to the mounting surface and prevent the unit from tipping forward.
NOTICE
If installing on a concrete floor, concrete fasteners are required and not included with the anti-tip kit.
Some installation sites may require modifications to provide a secure surface for attaching the
brackets.
A set of anti-tip brackets is supplied with the unit. These brackets should be attached to the floor at
the rear of the unit. Each bracket must be located to engage the rear legs when the cabinet is pushed
back into position. Refer to Figure 1 (shown below) for anti-tip bracket mounting locations.
PREPARING THE SPACE
PREPARING THE SPACE
If the unit is to be installed under a countertop, it is recommended that the countertop be supported
by a structure other than the unit itself to prevent damage to the unit.
Make sure the floor under the unit is level with the surrounding finished floor. Protect a finished
floor with plywood, cardboard, or some other suitable material before moving the unit into place.
Failure to do this may result in damage to the floor.
6
©2021 Hestan Commercial Corporation
RISK OF FIRE OR EXPLOSION - FLAMMABLE REFRIGERANT USED.
Use caution when handling, moving and using the product to avoid damaging
Anti-tip brackets are only used for stationary cabinets and should not be installed on
cabinets with accessory casters.
"
15
16
"
3
16
22-
"
3
16
Figure 1. 24" Anti-Tip Kit
BRACKETS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Grg_24Grr24Grfr24Grws_24Grwg_24Grs 24 serie ... Afficher tout

Table des Matières