Check that the control knobs on the grill is closed (OFF). Turn the tap on the gas bottle.
Apply solution of soap and water or ns. Article 1726 Revel gas in the tube and on all connections.
If bubbles appear, it means that there is a loss and it repaired before use.
After making the repair, repeat the test.
After conducting the test, close the gas supply to the tank.
If it is a leak is detected and you can not fix it, do not try to fix it another way, but instead use the assistance
service. In the case of gas leaks immediately close the valve of the gas cylinder.
1.
Check all the connections before using the appliance.
2.
Never work with the rubber hose not securely fastened by means of the above-mentioned metal clamps (3).
3.
Do not use the appliance if it is leaking, deteriorated or malfunctioning.
4.
Place the stove on a stable, horizontal, heating resistant and not flammable surface.
5.
Place the stove at a safe distance from inflammable materials and from objects that are sensitive to heat.
6.
Ensure that the tap (4) of the stove is CLOSED (clockwise rotation).
7.
Open completely the tap of gas cylinder.
8.
Turn clockwise the handwheel of the tap (4) to the maximum position.
9.
For models 104985, 104985D, 104986 and 104986D (traditional ignition): bring a flame to the burner (1).
For models 104986V and 104986VD (piezo-electric ignition): press the piezo ignition.
10. Make sure the burner is lit and regulate the flame according to your requirements.
11. If the flame is extinguished for any reason (blast of wind or spilled liquids), immediately close the taps of the
burner and the cylinder valve. Check the cause of the shutdown and restart if there are no problems with
the ignition process.
12. Place the pot upon the burner support, checking that it is in a stable position and the equipment is properly
balanced.
13. Ensure that the flame does not come out at the bottom of the pot large size.
14. Ensure that liquids do not come out off the pot and extinguish the flame.
15. Do not move the stove with working flame.
16. The body of the stove (base) may become hot during use. Handle exclusively using gloves.
5.
Recommended diameter of the vessels.
6.
ATTENTION: the maximum weight that the stove can support is 15 kg.
7.
Place the pan directly on the grill, making sure it is in perfect balance.
8.
Adjust the flame so as not to spill liquids into the pot, because they can switch off the burner.
1.
Close the tap on the gas cylinder.
2.
Close the tap on the stove.
3.
Wait until the stove has cooled down before putting it away.
1.
Dust, dirt and grease can reduce product performance and affect its safety.
2.
Frequently clean the product after use and before setting it aside in case of long periods of inactivity.
3.
Never clean the appliance immediately after use. Always wait for its cooling down.
4.
Before each cleaning or maintenance operation, always ensure that the cylinder valve is closed and the
appliance is in OFF position.
5.
Clean the frame with a wet cloth. Do not use abrasive substances, solvents and flammable products.
6.
In case of malfunction, never check the stove personally, but contact the dealer or qualified personnel.
Anyways, parts sealed by the manufacturer must not be altered by the user: any change to the appliance
can be dangerous.
7.
If the devise is unused for a long time, check the taps and the absence of dirt (or spiders) inside the burner.
8.
To preserve the life of your product, keep out of the rain, or store the product when it is cold in its original
packaging and store in a dry place and away from dust.
All questions of the departments services must be formulate to: KEMPER – Via Prampolini 1/Q – Lemignano di
Collecchio (PR) – Italy – Tel. +39 0521 957111 – Fax +39 0521 957195 – www.kempergroup.it –
info@kempergroup.it
There are some residual risks after the installation of the appliance that have to be considered:
Residual risks according to Regulation (EU) 2016/426 (annex 1, point 1.2):
DT Istr 104985-104986 – 02/2011 - Rev 12_07/2020
FUNCTIONING
USE OF RECIPIENTS
AFTER USE
CLEANING AND MAINTENANCE
MAINTENANCE – REPAIR
RESIDUAL RISKS
104985 – 104986 – 104986V