ALF1501D POWER SUPPLY INSTRUCTIONS MANUAL
1. PRELIMINARY INFORMATIONS
Manufacturer
: elc 59, avenue des Romains 74000 Annecy FRANCE
Phone : +33 (0)4 50 57 30 46 Fax : +33 (0)4 50 57 45 19
Instrument
: REGULATED SWITCHING POWER SUPPLY
Brand
: elc
: ALF1501D
Type
2. DESCRIPTION
2-1 Overview
You have just purchased the ALF1501D elc power supply. We thank you and congratulate
you for your good choice.
This device was manufactured in accordance with European standard EN 61010-1.
This instructions manual contains informations and warnings the buyer must comply with in
order to ensure safe and sustained operation.
It is intended for professional, industrial or educational uses.
2-2 Overall view
Switch ON / OFF
EEC socket
Voltage fine
adjustment
ON Indicator :
(-) voltage presence
ON Indicator :
(+) voltage presence
Output sockets
("-" ; "0" ; "+")
2-3 Technical features
The features of the instrument are given to the supply terminals at 23 °C.
Output voltage
: adjustable from ±10 V to ±15 V by potentiometer.
• +15V Output (only)
Charge regulation
: < 15 mV for a load change from 0 to 100%
Main regulation
: < 2 mV for a line change from -10 to +10%.
Total ripple
: < 3 mV rms
Switching freq. ripple
: < 3 mV peak to peak (with bandwidth 20 MHz).
Switching peak
: < 10 mV peak to peak (with bandwidth 20 MHz).
Low freq. ripple
: < 8 mV peak to peak
Dynamic regulation
: < 1% for a load change from 10 to 90%.
Efficiency
: > 78% for maximum power (30 W in output).
• -15 Volts Output (only)
Charge regulation
: < 10 mV for a load change from 0 to 100%
Main regulation
: < 2 mV for a line change from -10 to +10%.
Total ripple
: < 3 mV rms
Switching freq. ripple
: < 2 mV peak to peak (with bandwidth 20 MHz).
Switching peak
: < 15 mV peak to peak (with bandwidth 20 MHz).
Low freq. ripple
: < 4 mV peak to peak
Dynamic regulation
: < 5% for a load change from 10 to 90%.
• +20 to 30 V Output (available between output + and -)
Charge regulation
: < 15 mV for a load change from 0 to 100%
Main regulation
: < 2 mV for a line change from -10 to +10%.
Total ripple
: < 5 mV rms
Switching freq. ripple
: < 3 mV peak to peak (with bandwidth 20 MHz).
Switching peak
: < 30 mV peak to peak (with bandwidth 20 MHz).
Low freq. ripple
: < 12 mV peak to peak
Dynamic regulation
: < 5% for a load change from 10 to 90%.
Efficiency
: > 72% for maximum power (30 W in output).
• +15 Volts output current (only)
max I
: 3 A on 10 V ; 2.5 A on 12 V ; 2 A on 15 V
• -15 Volts output current (only)
max I
: 1 A on 10 to 15 V ; 1,1 A in short-circuit.
• ±10 to 15 Volts output current (or +20 to 30 V)
max I
: 1 A on ±10 to ±15 V.
• Global Power
Max power
: 30 W ; ±15 V - 1 A
• Visualisation
2 green LED "ON"
: positive and negative voltage present at the output.
• Protections
Against short-circuit by current limiting and disjunction.
Against overcurrent by internal fuse (T630mA 250V).
2.4 Other specifications
Input voltage
:
220-240 VAC (190 to 264 Volts), 50/60Hz
Power In
:
Max 40 W.
Efficiency
:
> 72% @ 30W output (±15 V - 1 A).
Insulation class
:
II, SELV output
Electric strenght
:
3000 VAC between input and output
Environmental
:
of use
: + 5 °C to + 40 °C
Conditions
storage : -10 °C to + 50 °C
moisture
:
see diagram (Fig. 1)
Protection level
:
IP 30
Safety
:
EN 61010-1 standard.
EMC
:
EN 61000-6-1 and EN 61000-6-3
Presentation
:
Polycarbonate case with screen printing.
Dimensions
:
H = 59 mm L = 106 mm
D = 95 mm (100mm with switch)
Weight
:
250 g
Input voltage
:
2 pin socket C8 type for IEC320 C7 cord.
DC output
:
Safety 4 mm sockets
2.5 Accessories of the instrument
Your ALF1501D is delivered with one double insulation cord with 2 poles and its
instructions manual.
3. INSTRUCTIONS FOR USE
3-1 Safety instructions
The instrument must be used according to the instructions of this manual.
Made to be used indoors, do not expose to the rain.
For a natural and correct cooling, the power supply must stand on its four rubber
thrusts and all ventilations must be widely cleared.
The plug of the feeding cable being used as the switch off device, the instrument
must be connected to a mains socket (230V 50/60Hz) easily accessible
No intervention is authorized inside the casing.
3-2 Use
Plug the power supply to the input voltage 220 - 240 V (O/I switch). The 2 green LED "ON"
lights up, your instrument is ready to work.
4. WORKING
ALF1501D is regulated, stabilised and protected power supply.
- Choose the symetrical output voltage thanks to the fine voltage adjustment.
- Connect the power supply on main, the 2 green LED light up.
- Connect the charge.
If the power required is higher than that the power supply can provide, a power limitation starts
(tripping), the 2 LED will turn off.
5. MAINTENANCE
No particular maintenance is required for this instrument.
Avoid dust, moisture, shocks : your instrument will be grateful for that.
If the green indicator does not light up when switching on, check :
- The mains voltage
- The connection to mains.
6. AFTER SALES SERVICE
During TWO YEARS, spare parts and workmanship are guaranteed. This guarantee does not
apply to instrument presenting defects or failures caused by an improper use. Return
expenses are borne by the client. Only devices returned with a dated purchasing invoice can
be recovered by the guarantee. Any intervention carried out by unauthorized persons or
organizations, shall void the guarantee.
7. DECLARATION OF CONFORMITY
Manufacturer
: ELC
59 avenue des Romains
74000 Annecy FRANCE
Phone
: +33 (0)4 50 57 30 46
Fax
: +33 (0)4 50 57 45 19
Website
: www.elc.fr
declares the product
Name
:
DC POWER SUPPLY (REGULATED SWITCHING POWER SUPPLY)
Type
:
ALF1501D
conformable to the requirements of the directives :
- Low voltage 2014/35/UE,
- Electromagnetic Compatibility 2014/30/UE,
%
- RoHs 2011/65/UE.
Fig. 1
80
The following harmonized standards have been applied :
50
maximum relative
moisture
Safety
:
EN 61010-1:2010
EMC
:
EN 61326-1:2013
°C
31
40
Annecy, on February 7, 2022
H. CURRI Manager
ELIMINATION OF MANUFACTURING WASTES BY THE PRIVATE
This symbol written in the product or in its packaging indicates that this
product must not be throw in the garbage with your other waste.
Its your responsability to rid of your manufacturing wastes bringing it to
a specialized sorting office for the recycling of electrical and electronic
instruments.
Collection and recycling separated of your wastes will contribute to
preserve natural resources and guarantee a recycling respectful of the
Environment and human health.
For further information concerning the recycling center near your place
of residence, contact your town hall, the elimination service of garbage
heap or the store where you bought the instrument.
G
USERS IN THE EU
B