Télécharger Imprimer la page

ELC ALF1210 Notice D'instructions page 2

Publicité

Les langues disponibles

Les langues disponibles

ALF1210 POWER SUPPLY INSTRUCTIONS MANUAL
1. PRELIMINARY INFORMATIONS
Manufacturer
: elc 59, avenue des Romains 74000 Annecy FRANCE
Phone : +33 (0)4 50 57 30 46
Fax : +33 (0)4 50 57 45 19
Web site : www.elc.fr
Instrument
: SWITCHED AND REGULATED POWER SUPPLY
Brand
: elc
Type
: ALF1210
2. DESCRIPTION
2-1 Overview
You have just purchased the ALF1210 elc power supply. We thank you and
congratulate you for your choice.
This device was manufactured in accordance with European standard EN 61010-1.
This instructions manual contains informations and warnings the buyer must comply
with in order to ensure safe and sustained operation.
It is intended for professional, industrial or educational uses.
2-2 Overall view
Fine voltage
adjustment
STATUS Indicator
ON indicator :
voltage presence
EEC socket
Output
sockets "+"
and "-"
2-3 Technical features at 23°C at the terminals of the power supply
Output voltage
: adjustable from 10 V to 15 V by potentiometer.
Total ripple
: < 3 mV rms
Low freq. ripple
: < 5 mV peak to peak
Switching freq. ripple : < 5 mV peak to peak (with bandwidth 20 MHz).
Switching peak
: < 40 mV peak to peak (with bandwidth 20 MHz).
Charge regulation
: < 25 mV for a load change from 0 to 100%.
Main regulation
: < 1mV for a line change from -10 to +10%.
Dynamic regulation
: < 1% for a load change from 10 to 90%.
Internal resistance
: < 3 mΩ
Hold-up time
: 25 ms at load 50% and 12 ms for 100 % mains at 200 V.
Efficiency
: >80 % for maximum power (150 W in output).
Output current
: 10 A, 10,5 A in short-circuit.
Power
: 150 W to 15 V, 120 W to 12 V, 100 W to 10 V
Protections
: against short-circuit by current limiting.
against overcurrent by internal fuse T3.15A.
against output overvoltage (17 V).
against a fan defect by thermal circuit breaker.
Main input voltage
: 190 to 264 V, 50/60 Hz
Insulation class
: I I
Electric strenght
: 3000 V between input and output
1500 V between earth and input
Environmental
: of use : + 5 °C to + 50 °C
Conditions
storage : -10 °C to + 50 °C
moisture : see curve (D. 1)
Protection level
: IP 30
Safety
: EN 61010-1, overvoltage category ll and pollution degree 2.
EMC
: EN 55011, group 1, class B. EN 61000-6-1 Aptitude criteria A.
Dimensions
: L = 120 mm H = 60 mm D = 120 mm
Presentation
: metal case with epoxy finish and screen print.
Weight
: 860 g
Input voltage
: EEC socket with 2 poles.
DC output
: Safety 4 mm sockets.
2.4 Accessories of the instrument
Your ALF1210 is delivered with one double insulation cord with 2 poles (CEE 7/16
- CEE 22 C7) and its instructions manual.
3. INSTRUCTIONS FOR USE
3.1 Safety instructions
The instrument must be used according to the instructions of this manual.

Made to be used indoors, do not expose to the rain.
For a natural and correct cooling, the power supply must stand on its four rubber
thrusts and all ventilations must be widely cleared.
The plug of the feeding cable being used as the switch off device, the instrument
must be connected to a mains socket easily accessible and near.
No intervention is authorized inside the casing.
3-2 Use
Plug the power supply to the main input voltage 220 -240 V and switch it on (O/I switch).
The green LED lights up (ON : voltage presence), your instrument is ready to work.
4. WORKING
ALF1210 is a regulated and protected power supply that allow an use in limit case
of operation :
- Choose the output voltage thanks to the fine voltage adjustment.
- Connect the power supply on main, the green LED lights up.
- Connect the charge.
If required current is superior to the one that the ALF1210 can supply, a limitation starts
and the red LED lights up.
Fan only works when necessary.
5. MAINTENANCE
No particular maintenance is required for this instrument.
Avoid dust, moisture, shocks : your instrument will be grateful for that.
If the green indicator does not light up when switching on, check :
- The mains voltage presence.
Switch
ON/OFF
- The connection to mains.
If the STATUS red led indicator lights up, either the power supply has a defect and
its output is limited to 17 V, or the fan has a defect and the output is cut. In this case,
please send the power supply back to our after sales service.
6. AFTER SALES SERVICE
During TWO YEARS, spare parts and workmanship are guaranteed. This guarantee
does not apply to instrument presenting defects or failures caused by an improper use.
Return expenses are borne by the client. Only devices returned with a dated purchasing
invoice can be recovered by the guarantee. Any intervention carried out by
unauthorized persons or organizations, shall void the guarantee.
Graph1
7. EU DECLARATION OF CONFORMITY
Manufacturer
: ELC
59 Avenue des Romains
74000 Annecy FRANCE
Phone : +33 (0)4 50 57 30 46
declares the product
Name
: SWITCHED AND REGULATED POWER SUPPLY
(DC power supply)
Type
: ALF1210
conformable to the requirements of the directives :
Low voltage 2014/35/UE, Electromagnetic Compatibility 2014/30/UE and
RoHs 2011/65/UE.
The following harmonized standards have been applied :
Safety
: EN 61010-1:2010
EMC
: EN 61326-1:2013
Annecy, on January 18, 2022
H. CURRI Manager
ELIMINATION OF MANUFACTURING WASTES BY THE
PRIVATE USERS IN THE EU
This symbol written in the product or in its packaging indicates that this
product must not be throw in the garbage with your other waste.
Its your responsability to rid of your manufacturing wastes bringing it to a
specialized sorting office for the recycling of electrical and electronic
instruments.
Collection and recycling separated of your wastes will contribute to
preserve natural resources and guarantee a recycling respectful of the
Environment and human health.
For further information concerning the recycling center near your place of
residence, contact your town hall, the elimination service of garbage heap
or the store where you bought the instrument.