C Rotary controller for timer of channel 1 ("TIMER1")
Setting the time (0.5 to 25 seconds) for which the relay of channel 1 remains active (turn left
counter-clockwise for shorter, turn right for longer duration)
D Rotary controller for timer of channel 2 ("TIMER2")
Setting the time (0.5 to 25 seconds) for which the relay of channel 2 remains active (turn left
counter-clockwise for shorter, turn right for longer duration)
E Control connection for channel 1
"Hi CONTROL 1": Trigger activation by high potential (+12 V/DC)
"Lo CONTROL 1": Trigger activation by low potential (GND/Earth)
F Control connection for channel 2
"Hi CONTROL 2": Trigger activation by high potential (+12 V/DC)
"Lo CONTROL 2": Trigger activation by low potential (GND/Earth)
G Jumpers for timer activation of channel 1
"Hi" = Timer activation by high potential (+12 V/DC)
"Lo" = Timer activation by low potential (GND/Earth)
Jumper position "0" = Use of external timer (e.g. code lock)
Jumper position "1" = Use of internal timer, time is set at emergency power supply with rotary
control "C")
H Jumpers for timer activation of channel 2
"Hi" = Timer activation by high potential (+12 V/DC)
"Lo" = Timer activation by low potential (GND/Earth)
Jumper position "0" = Use of external timer (e.g. code lock)
Jumper position "1" = Use of internal timer, time is set at emergency power supply with rotary
control "D")
31