does not flash the control panel is not operational or the
databus is faulty (usually cabling).
TX: LED flashes to indicate the DGP is replying to polling from
the ATS control panel. If the RX LED flashes but the TX LED
does not, it indicates that the DGP is not programmed to be
polled in the control panel or that it is addressed incorrectly.
Zone numbering
Table 1: Zone and output numbering
Control panel
1–16
DGP1
17–32
DGP2
33–48
DGP3
49–64
DGP4
65–80
DGP5
81–96
DGP6
97–112
DGP7
113–128
ATS1210(L)E and ATS1211E have eight zones on-board.
ATS1210LE can be equipped with ATS1202 eight-zone
expansion module that expands zone number to 16.
There are 16 zones allocated to every DGP address. If zones 9
to 16 are not available, they should be programmed as type 0
(zone disabled) in the Zone database.
Output numbering
See Table 1 above.
A DGP can have a maximum of 16 outputs available as relays
or open collector outputs. The output numbers are the same as
the 16 zone numbers allocated to the DGP address.
The output numbers can be used if output controllers are
connected to the DGP that corresponds to those output
numbers.
Examples:
•
DGP1 has 8 zones: 17 to 24
•
DGP1 outputs (max 16): 17 to 32
Programming
The programming map is shown in Figure 5.
See Advisor Master Programming Guide for more details on
the DGP programming.
Extended mode
To enable anti-mask detection it is necessary to select
Extended mode. Standard mode is needed for backwards
compatibility. Default is Extended mode.
Technical specifications
Supply voltage
Current consumption
Data retention
Dimensions (H x W) (size BB board)
P/N 1077869 (ML) • REV A • ISS 09MAR17
DGP8
129–144
DGP9
145–160
DGP10
161–176
DGP11
177–192
DGP12
193–208
DGP13
209–224
DGP14
225–240
DGP15
241–256
10.5 to 13.8 V
(12 V
nom.)
53 mA max.
> 40 years
90 x 80 mm
Housing dimension (H x W x L):
ATS1643 small metal housing
ATS1644 small plastic housing
ATS1647 large plastic housing
Weight
ATS1211E
ATS1210E
ATS1210LE
Operating temperature
IP rating
Relative humidity
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
EN 50131-1 System requirements
EN 50131-3 Control and indicating equipment
Security Grade 3, Environmental class II
Tested and certified by Telefication B.V.
UTC Fire & Security hereby declares that this device is
in compliance with the applicable requirements and
provisions of one or more of the Directives 2014/30/EU
and 2014/35/EU. For more information see
www.utcfireandsecurity.com or www.interlogix.com.
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.utcfssecurityproducts.eu
DE: Installations Beschreibung
Anwendungsbereich
ATS1210(L)E und ATS1211E sind abgesetzte Erweiterungen
mit 8 MG für das Advisor Master System.
Montage der Erweiterung
Die Platine kann in jedem vorhandenen Gehäuse der ATS-
Serie montiert werden, welches das BB-Format unterstützt.
Die AME kann auch in einem der nachfolgenden separaten
Gehäuse montiert werden: ATS1644 (Kunststoff), ATS1647
(Kunststoffgehäuse, groß) und dem ATS1643 (Metall). Die
Gehäuse mit Montagelöchern (Position 1) sind in den
Abbildungen 2 bis 4 dargestellt. Position 2 und 3 zeigen
165 x 125 x 36mm
86 x 125 x 36 mm
120 x 240 x 38 mm
790 g
190 g
390 g
−10 to +55°C
IP30
< 95%, noncondensing.
3 / 16