Decommissioning; Maintenance And Cleaning - Renkforce 1519498 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Decommissioning

If the dirt water pump is to be disconnected from the hose (e.g. for cleaning, maintenance or storage in winter),
proceed as follows:
• Disconnect the dirt water pump from the power supply, pull the mains plug from the mains socket.
• Pull the dirt water pump from the water by the attachment rope or carry handle.
The dirt water pump must never be pulled out by the mains cable or hose! This may damage the mains
cable; there is danger to life from electric shock!
• Disconnect the hose from the dirt water pump.
• Let residual water run out of the dirt water pump by holding it diagonally.
• Dry the dirt water pump and the mains cable. Coil up the mains cable.
• Store the dirt water pump in a frost-protected and dry room over winter.
Also consider emptying the hoses placed outdoors to prevent frost damage; open any water taps that may
be installed.
• Carry or transport the dirt water pump only by the carry handle. Never hold it by the hose or even the mains cable.
• After operation or emptying, a small amount of water may remain in the dirt water pump. Therefore, use a suitable
support when storing or transporting it in a vehicle.

10. Maintenance and Cleaning

The dirt water pump has no parts that require maintenance by you. Therefore, never open or disassemble it. Mainte-
nance or repair and opening of the dirt water pump in this context must only be performed by a specialist or specialist
workshop.
Before cleaning, switch off the dirt water pump and disconnect it from the mains voltage; pull the mains plug from the
mains socket.
To clean the outside of the dirt water pump, a dry, soft and clean cloth is sufficient. If required, flush the outside with
clear water.
Any contamination of intake openings may be removed under running water (e.g. garden hose). The dirt water pump
inside may be flushed with running water as well by removing the hose and any connection piece.
Dry the dirt water pump and the mains cable before storing it.
Never use any aggressive cleaning agents, cleaning alcohol or other chemical solutions, since these may
damage the casing or even impair function.