3.
The smaller the gauge number of the wire, the greater the capacity of the cord. For
example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table
A.)
4.
When using more than one extension cord to make up the total length, make sure
each cord contains at least the minimum wire size required. (See Table A.)
5.
If you are using one extension cord for more than one tool, add the nameplate amps
and use the sum to determine the required minimum cord size. (See Table A.)
6.
If you are using an extension cord outdoors, make sure it is marked with the suffix "W-
A" ("W" in Canada) to indicate it is acceptable for outdoor use.
7.
Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified
electrician before using it.
8.
Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
NAMEPLATE
AMPERES
(At Full Load)
0 – 2.0
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
SKU 94245
All manuals and user guides at all-guides.com
Table A
(120 VOLT)
EXTENSION CORD LENGTH
25
50
Feet
Feet
18
18
18
18
18
18
18
16
16
14
14
12
12
10
SYMBOLOGY
Table B
For technical questions, please call 1-800-444-3353
75
100
Feet
Feet
18
18
18
16
16
14
14
12
12
10
10
-
-
-
150
Feet
16
14
12
12
-
-
-
English