7. Backup battery
6.1.3
6.2 Programme SREL3
7 Backup battery
30 / 120
Push to open
Relay 1 can be used for a push-to-open function. The
relay is closed if Inputs I+ and I3 are connected to one
another.
Make sure that the SREL3 is connected correctly.
Use a USB cable to connect the SREL3 controller
to your computer for initial programming.
Power is supplied either via PoE or from a power
supply unit.
SREL3 readers (SREL3.EXT.G2.W[.WP]) can be
programmed during initial programming or via a
network connection at a later date.
LSM software Version 3.3 SP2 or higher is required
as a minimum for programming the SREL3.
You will find can find more information on using the
LSM software in the SimonsVoss manuals at
www.simons-voss.com
An empty backup battery may cause the internal clock
to stop in SmartRelays. We therefore recommend
checking the time on the clock at regular intervals. A
backup battery will last for about ten years if the
power supply to the SmartRelay is not interrupted.
This battery should be replaced on a regular basis if
SmartRelay draws on the backup battery at regular
intervals due to frequent power failures.
SmartRelais 3 Controller
.