Incandescent / Halogen
120 V Dimmer
Rated at 120 V~ 60 Hz 600 W
S-600PE, S-603PE
Important Notes
Please read before installing.
1. CAUTION: Use only with permanently-installed 120 V incandescent or
halogen fixtures. To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting fixtures,
motor-driven appliances, or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. Only one dimmer can be used in a 3-way circuit.
4. With the Eco-Dim
switch set to "Eco", the lights are slightly dimmed at
TM
the highest light level for 15% energy savings. With the switch set to
"Normal", the dimmer will provide normal energy savings. In either
mode, dim down further for more savings.
5. When no "grounding means" exist within the wallbox then the NEC
dimmer without a grounding connection to be installed as a replacement, as long as a plastic, non-
combustible wallplate is used. For this type of installation, cap or remove the green ground wire on
the dimmer and use an appropriate wallplate such as Lutron's Claro
6. For new installations, install a test switch before installing the dimmer.
7. Protect dimmer from dust and dirt when painting or spackling.
8. Recommended minimum load is 40 W.
9. It is normal for the dimmer to feel warm to the touch during operation.
10. Clean dimmer with a soft damp cloth only . Do not use any chemical cleaners.
Multigang Installations
When installing more than one control in the same
wallbox, it may be necessary to remove all inner
side sections prior to wiring (see diagram). If pre-
installed, remove the Lutron wallplate and
wallplate adapter from dimmer. Using pliers, bend
side section up and down until it breaks off.
Repeat for each side section to be removed.
Removal of dimmer side sections reduces maxi-
mum load capacity. Refer to chart below for maxi-
mum dimmer capacity.
Dimmer Capacity Chart
Dimmer
No sides
R
i t a
g n
e r
m
v o
d e
6
0 0
W
6
0 0
W
Technical Assistance
?
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center . Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1.800.523.9466
Other countries 8am – 8pm ET
+1.610.282.3800
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service,
return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE
YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULT-
ING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CON-
SEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE,
SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have
other rights which vary from state to state. Some states do not
• Easy-to-follow
allow the exclusion or limitation of incidental or consequential
damages, or limitation on how long an implied warranty may
Instructions
last, so the above limitations may not apply to you. Lutron, Claro,
• Instructions
and Glyder are registered trademarks and Eco-Dim is a trade-
mark of Lutron Electronics Co., Inc. NEC is a registered trade-
faciles à suivre
mark of the National Fire Protection Association, Quincy,
Massachusetts. © 2010 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A.
10/10 P/N 030-1354 Rev. A
Lutron Technical Support Center
English
Installation
1
Normal
Eco-Dim
2
TM
Switch
Eco
2005, Article 404-9 allows a
®
series wallplates.
®
3
Do Not Remove
Outside Sections
SINGLE-POLE:
Insulated wires connected
to two screws of the same
Each Control Has Inside
Middle Control Has Two
color. Replace with a SIN-
Sections Removed
Side Sections Removed
GLE-POLE dimmer. See
1 side
2 sides
Step 5a.
e r
m
v o
d e
e r
m
v o
d e
4
5
0 0
W
4
0 0
W
Important Note: Your wall switch may have two wires attached to the same screw (see
illustrations below for examples). Tape these two wires together before disconnecting.
Connect both wires to the dimmer wire in Step 5.
Fax +1.610.282.6311
http://www.lutron.com
• Easy-to-follow
Instructions
• Instructions
faciles à suivre
030-1354
030-1354
1.800.523.9466
Turning OFF Power.
• Turn power OFF at circuit breaker (or remove fuse).
Removing Wallplate and Switch.
• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Caution: Verify power
is OFF to switch
before proceeding.
Identifying the Type of Circuit.
Different-colored screw (Common).
Actual location may vary.
OR
Ground (Bare
Copper or
Green Wire)
Ground (Bare Copper
or Green Wire)
Tag
3-WAY:
Insulated wires connected to three screws. One of
OR
these wires is connected to a screw of a different-
color (not green) or labeled COMMON. MARK or
TAG this wire to identify it when wiring. Replace
with a 3-WAY dimmer. See Step 5b.
Disconnecting Switch Wires.
One wire in the
backwired hole
and one to the
screw.
24 hrs / 7 days
www.lutron.com
5
Wiring the Dimmer.
• For installations involving more than one control in a wallbox, refer to the
section on Multigang Installations before beginning.
Note: Wire location will vary by product. Reference wires by color, not loca-
tion.
5a - Single-Pole Wiring
Black
Ground
Green
Black
Black
120 V~
Green
60 Hz
Light
Ground
5b - 3-Way Wiring
Tag
Black
Green
Red
Black
Red
120 V~
Green
Red
60 Hz
Dimmer
3-Way Switch
Ground
6
Mounting Dimmer to Wallbox.
One continuous
• Form wires carefully into the wallbox, mount and align dimmer.
wire to the
• Install wallplate.
screw.
Start screws.
Screw Terminals:
Turn screws to
loosen.
7
Turning ON Power.
• Turn power ON at circuit breaker (or replace fuse).
Push-in Terminals:
Insert screwdriver. Pull
wire out.
Looped Wire:
Turn screws to loosen.
• Connect the green dimmer ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 4.)
• Connect one of the black dimmer
wires to either of the wires
removed from the switch.
• Connect the remaining black dim-
mer wire to the other wire
removed from the switch.
Note: To use a 3-Way dimmer
(one black and two red wires) in a
single-pole application, cap off one
of the red wires and follow
instructions for single-pole wiring.
(If the on/off switch works back-
wards, switch the red wires.)
• NOTE: Only one dimmer can be
used in a 3-WAY circuit.
• Connect the green dimmer ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 4.)
• Connect the black dimmer wire to
the wire removed from the differ-
ent-colored screw on the switch
(marked or tagged wire). Remove
tag from wire.
Ground
• Connect one of the red dimmer
wires to either of the remaining
wires removed from the switch.
• Connect the remaining red dim-
mer wire to the remaining wire
Light
removed from the switch.
Align dimmer and