ENGLISH
1) MODULAR DETECTION AND CONTROL ASSEMBLY FOR SANITARY USE
INSTALLATION AND OPERATING INSTRUCTIONS
2) URINAL WITH WASHING TIME DELAY 3 to 16s
3) WASHBASIN WITH closing time delay 1 to 30 s
4) 230 V - 50/60 Hz - Ø7 max
5) L=2m – Grey
6) L=2m – Orange
7) B or B'
8)
PART NUMBER
WASHBASIN/
SHOWER
x
52460
x
52461
x
52462
52463
52464
52465
52466
52467
52468
90295
x
90297
90296
x
90455
90324
29851
9) RECOMMENDATIONS FOR THE USE OF THE WASHBASIN
10) SPOUT INSTALLED ON RACK
11) WALL-MOUNTED SPOUT
12) INSTALLATION UNDER THE SPOUT
13) INSTALLATION ABOVE THE SPOUT
14) USING THE URINAL
15) USING THE SHOWER
16) GENERAL INSTALLATION PRECAUTIONS
17) Never place a mirror facing the detection
18) INSTALLING THE DETECTOR
19) SILICON for shower
20) For version 10 to 50 mm
21) Adjustment before installation
22) HYDRAULIC SUPPLY
23) USE
24) INSTALLATION OF THE ELECTRONIC CIRCUIT
25) Installation recommendation:
* Position the glands in the bottom part.
* Do not install the circuit at a location likely to receive water discharge.
26) POWER SUPPLY
· The power supply of the circuit must be provided by an authorised person, according to rules of NFC 15-100.
· It is recommended to provide an independent supply by a device connected to a cut-out switch fitted with a protective device (fuse or circuit breaker)
rated at 2A.
· Before any intervention on the switch box, it is mandatory to switch off its electrical supply.
27) 1 mm max
28) Strip the sheath by 100 mm
29) SHEATHED CABLE 2x1 mm² Ø7 mm max
30) Connect the sheath Q to the solenoid valve
31) START UP
· Depending on your use, configure the circuit if required, with power off according to the indications below.
· Power on, verify the operation.
· If the detection does not occur at the desired distance, alter the range and verify the operation by putting the detector back in place.
· If the operation is not correct, refer to the "maintenance" chapter.
32) ADJUSTMENTS
· The adjustments inside the box must be made by an authorised person, after disconnecting the power.
· Only the cell range can be adjusted with power on (provided that the cover has been properly closed).
URINAL
WASHBASIN/SHOWER DETECTION ASSEMBLY FOR
PARTITION 0-10 MM
WASHBASIN/SHOWER DETECTION ASSEMBLY FOR
PARTITION 10-50 MM
WASHBASIN/SHOWER DETECTION ASSEMBLY FOR
PARTITION 50-200 MM
x
ORDINARY URINAL DETECTION ASSEMBLY FOR
PARTITION 0-10 MM
x
ORDINARY DETECTION ASSEMBLY FOR PARTITION 10-50
MM
x
ORDINARY DETECTION ASSEMBLY FOR PARTITION 50-
200 MM
x
SIPHON URINAL DETECTION ASSEMBLY FOR PARTITION
0-10 MM
x
SIPHON DETECTION ASSEMBLY FOR PARTITION 10-50
MM
x
SIPHON DETECTION ASSEMBLY FOR PARTITION 50-200
MM
MODULAR DETECTION CONTROL CIRCUIT FOR WASHBASIN A
x
MODULAR DETECTION CONTROL CIRCUIT FOR URINAL
x
DETECTION CELL ONLY
SOLENOID VALVE DN10 + FILTER
SOLENOID VALVE DN13 + FILTER
INLET SHUT-OFF VALVE M G1/2 - OUTLET F G3/4 SWIVEL NUT
DESCRIPTION
COMPOSITION
A-B-C to Q
A-B-C to Q
A-B-C to Q
A-B-C to Q
A-B-C to Q
A-B-C to Q
A-B'-C to Q
A-B'-C to Q
A-B'-C to Q
A
E + F + H
B + C
B' + C
D + C