DIP Switches Settings

Module
Dip Switch
PS/SW1-
SW3
PS/SW4
Power
Supply
UO/ SW1-
SW3
UO/SW4
Utility
output
NOTE:
When PS/SW4, or UO/SW4 is Off, the ID number defined by SW1-SW3 is not
recognized by the ProSYS and can be used for the connection of another accessory
of the same category. The UO/PS LED will flash since there is no communication with
the main panel.

Jumper Settings

Jumper
Description
Battery discharge protection
Protection
ON
BAT
Protection
OFF
Description
Used to set a unique ID number for the Bus
module for communication purposes.
Enables/Disables Power Supply - ProSYS
communication
On (up): Communication enabled.
Off (down): Communication disabled
Used to set a unique Bus ID number for the UO
module located on the SMPS board.
Enables/disables UO module - ProSYS
communication.
On (up): communication enabled.
Off (down): communication disabled
If a continuous AC power outage occurs, the
SMPS automatically disconnects the battery when
its backup battery voltage drops below 10.8VDC.
This is done to prevent "deep discharge" that may
damage the battery.
The battery may be totally discharged during
continuous AC failure (no deep discharge
protection).
NOTE:
If 2 pins configuration is selected, the battery might be damaged,
thus battery replacement may be required.