Thank you for buying this product, our company is sure that you
will be more than satisfied with the product's performance. The
product is supplied with a "Warnings" leaflet and an "Instruction
booklet". These should both be read carefully as they provide
important information about safety, installation, operation and
maintenance. This product complies with the recognised technical
standards and safety regulations. We declare that this product is
in conformity with the following European Directives: 89/336/
EEC and 73/23/EEC (and subsequent amendments).

GENERAL SAFETY

WARNING! An incorrect installation or improper use of the
product can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied
with this product should be read carefully as they provide
important information about safety, installation, use and
maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc)
according to the provisions set out by current standards.
Keep nylon or polystyrene bags out of children's reach.
Keep the instructions together with the technical brochure for
future reference.
This product was exclusively designed and manufactured for
the use specified in the present documentation. Any other
use not specified in this documentation could damage the
product and be dangerous.
The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is
different from that expected and specified in the present
documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply
with the following European Directives:It complies with the
89/336/EEC, 1999/5/CEE,
subsequent amendments. As for all non-EEC countries, the
above-mentioned standards as well as the current national
standards should be respected in order to achieve a good
safety level.
The Company declines all responsibility for any consequences
resulting from failure to observe Good Technical Practice
when constructing closing structures (door, gates etc.), as
well as from any deformation which might occur during use.
The installation must comply with the provisions set out by the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
Disconnect the electrical power supply before carrying out
any work on the installation. Also disconnect any buffer
batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains
power supply, having a contact opening distance equal to or
greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted
just before the power supply mains.
Check that earthing is carried out correctly: connect all metal
parts for closure (doors, gates etc.) and all system components
provided with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.)
which are needed to protect the area from any danger caused
by squashing, conveying and shearing.
Position at least one luminous signal indication device (blinker)
where it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the
automation safety and correct operation when other
manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly
authorised by the company.
8 - CLONIX/TRC/MITTO - Ver. 05
INSTALLATION MANUAL
European Directive and
Instruct the product user about the control systems provided
and the manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
operation area.
Keep radio control or other control devices out of children's
reach, in order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair
on the automation system, and always request the assistance
of qualified personnel.
Anything which is not expressly provided for in the present
instructions, is not allowed.
Installation must be carried out using the safety devices and
controls prescribed by the EN 12978 Standard.

1) GENERAL OUTLINE

The Clonix receiver combines the characteristics of utmost
safety in copying variable code (rolling code) coding with the
convenience of carrying out transmitter "cloning" operations
thanks to an exclusive system.
Cloning a transmitter means creating a transmitter which can be
included automatically within the list of the transmitters memorised
in the receiver, either as an addition or as a replacement of a
particular transmitter.
Therefore it will be possible to remotely program a large number
of additional transmitters, or for example, replacement transmitters
for those which have been lost, without making changes directly
to the receiver. Cloning by replacement is used to create a new
transmitter which takes the place of the one previously memorised
in the receiver; in this way the lost transmitter is removed from the
memory and will no longer be usable
When coding safety is not a decisive factor, the Clonix receiver
allows you to carry out fixed code additional cloning, which
although abandoning the variable code, provides a high number
of coding combinations.
Using clones when there is more than one receiver (as in the case
of communal buildings),
and especially when a distinction is to be made between clones
to be added to or replaced in individual or collective receivers,
could turn out to be rather difficult. The Clonix receiver cloning
system for communal buildings makes it particularly easy to
solve the problem of clone storage for up to 250 individual
receivers.

2) TECHNICAL SPECIFICATIONS

Frequency
: 433.92MHz
Working temperature : -20 / +55°C
Coded by means of
: Rolling-code algorithm
No. combinations
: 4 milliard
Dimensions
: see fig.1
2.1) Receiver
Power supply
: from 12 to 28V= - from 16 to 28V~
Antenna impedance
: 50Ohm (RG58)
Relay contact
: 1A - 33V~, 1A - 24V=
Max no. radio transmitters to be memorised:
Receiver version
No. radio transmitters
CLONIX 128
128
CLONIX 512
512
CLONIX 2048
2048
Single-channel, double-channel.
2.2) MITTO Transmitter 12V
Keys
: Grey
Power supply
: 12V Alkaline battery
Range
: 50 / 100 metres
Transmitter versions:
Double-channel, four-channel.