If Super Switch is available:
Super switch
(In some models)
• Normally set this switch to '0' position.
Except when the ambient temperature
is low like in winter. (ie.below 16°C) or
when the freezer temperature needs to
be maintained lower. In that case, turn
the switch to '1' position ON.
• To set super switch ON that is on the
thermostat box, press the switch down to
'1' position. The switch will lit.
• When the freezer compartment is cooled
down to sufficient temperature, or the
weather gets hot, turn the super switch
off to save electrical consumption.
• When you first switch on the appliance,
for starting a suitable cooling, the
appliance should work 24 hours
continuously until it cools down to
sufficient temperature.
• In this time do not open the door so
often and place a lot of food inside the
appliance.
If the unit is switched off or unplugged,
you must allow at least 5 minutes before
restarting or re-plugged the unit in order not
to damage the compressor.
Super freezing: If ambient temperature
is more than 16
C, this switch must be
o
used as superfreeze switch. For maximum
freezing capacity, please turn on this switch
when placing fresh food. After placing fresh
food in the freezer, 24 hours ON position is
generally sufficient. In order to save energy,
please turn off this switch after 24 hours
from placingfresh food.

3.2 Temperature Settings Warnings

• The ambient temperature, temperature of
the freshly stored food and how often the
door is opened affects the temperature in
the refrigerator compartment. If required,
change the temperature setting.
• It is not recommended that you operate
your fridge in environments colder than
10°C in terms of its efficiency.
• When setting the thermostat, take into
consideration how often the appliance
doors are opened and closed, how much
food is stored in the refrigerator, and the
environment in which the refrigerator is
located.
• When the appliance is first switched on,
allow it to run for 24 hours in order to
reach operating temperature. During this
time, do not open the door and do not
keep a large quantity of food inside.
• Unplug your appliance during a power cut
to prevent damage to the compressor.
Once power is restored, delay plugging
in your appliance for 5 to 10 minutes.
This will help prevent damage to the
appliance's components.
• Your appliance is designed to operate in
the ambient temperature ranges stated
in the standards, according to the climate
class stated in the information label. It
is not recommended that your fridge is
operated in the environments which are
outside of the stated temperature ranges.
This will reduce the cooling efficiency of
the appliance.
• Your appliance is designed to operate in
the ambient temperature (T/SN = 10°C
- 43°C) intervals stated in the standards,
according to the climate class displayed
on the information label. We do not
recommend operating your appliance out
of the stated temperature limits in terms
of cooling effectiveness.
Climate
Class
T
ST
N
SN
EN - 30
Ambient Temperature
Between 16 and 43 (°C)
Between 16 and 38 (°C)
Between 16 and 32 (°C)
Between 10 and 32 (°C)