APPLICATION
Eaton's Crouse-Hinds Division Electrical Construction Materials EDS and EDSC Series Single and Two
Gang Device Bodies are intended for use with Crouse-Hinds series DS and DSD Control Station Covers,
and Crouse-Hinds series CPS, ENR and GFS Receptacle and Ground Fault Circuit Interrupter Covers.
When properly assembled, the complete assemblies are suitable for use in Class I and Class II hazardous
(classified) locations as defined by the National Electrical Code
(CEC). Refer to specific application information published in Crouse-Hinds series catalog or to information
INSTALLATION
Electrical power must be turned OFF before and during installation and maintenance.
1.
Select a mounting location that will provide suitable strength and rigidity for supporting all
contained wiring and control devices. Figure 1 shows mounting dimensions for EDS, EDSC, EFS
and EFSC Device Bodies. Drill mounting holes for 5/16 inch diameter mounting hardware.
2.
Securely fasten body to the mounting surface, then attach into conduit system. Install approved
conduit sealing fittings when required. Read CAUTION statement below.
Conduit sealing fittings may be required to be installed to comply with the requirements of
the CEC or NEC, Section 501-5 and/or 502-5, plus any other applicable standards. Refer to
information published in Crouse-Hinds series catalog or to information in the Installation and
Maintenance Information Sheet for each cover to be installed on the EDS, EFS and EDSC
Bodies to determine the need for sealing fittings.
All unused conduit openings must be plugged with Crouse-Hinds series PLG plugs that are
approved for hazardous areas. Plugs must engage a minimum of five (5) full threads and be a
minimum of 1/8 inch thick.
3.
Select the proper cover for assembly. Similar cover and back box materials can only be used (e.g.
iron with iron; aluminum with aluminum). Refer to the Installation and Maintenance Information
Sheet provided with each cover to complete the installation.
MAINTENANCE
Always disconnect primary power source before opening enclosure for inspection or service.
Hammers or prying tools must not be used; they may damage the flat ground joint surfaces. Do not
handle covers roughly, or place them on surfaces that might damage or scratch the flat ground joint
surfaces. Keep mating surfaces clean of dirt, grit or other foreign materials.
1.
Regular inspection should be made. A schedule for maintenance should be determined by the
environment and frequency of use. It is recommended that it should be at least once a year.
2.
Perform visual, electrical and mechanical checks on all components on a regular basis.
Visually check for undue heating evidenced by discoloration of wires or other components,
damaged or worn parts or corrosion in the interior.
Electrically check to make sure that all connections within the enclosure are clean and tight, and
that contacts in the components make or break as required.
Mechanically check that all parts are properly assembled, and operating mechanisms move freely.
Check to see that the ground joint surfaces of the body and cover are free of scratches, mars, grit
or other imperfections that might impair mating of the two components and the explosionproof
and dust-ignitionproof integrity of the product in operation.
Check all cover screws to make sure that they have been tightened with a screwdriver and cannot
be removed by hand.
3.
We recommend an Electrical Preventive Maintenance program as described in the National Fire
Protection Association Bulletin NFPA No. 70B.
EDS Series Single Gang
Hub
Dead End
Size
Cat. #
1/2"*
EDS171
3/4"
EDS271
1"
EDS371
EDS Series Typical Body
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not guaranteed. In accordance with
Eaton's Crouse-Hinds Division's "Terms and Conditions of Sale," and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes
all risk and liability whatsoever in connection therewith.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
®
(NEC) and Canadian Electrical Code
WARNING
!
!
CAUTION
!
WARNING
!
CAUTION
Two Gang
Through Feed
Dim.
Dim.
Cat. #
a
b
EDSC171
3/4
13/16
EDSC271
7/8
13/16
EDSC371
1
15/16
Side View
1201 Wolf Street, Syracuse, NY 13208 • U.S.A. Revision 4
provided on the products to determine the hazardous location suitability of each of the many cover/body
combinations which are available.
The XT suffix provides an expanded temperature range of -50°C to +60°C for EDS and EFS Assemblies,
DSD and DS Covers and FlexStation™ Components. For iron assemblies, only EDS iron back boxes
externally marked with an "X" on the conduit hub can be assembled with XT suffix iron covers. All
aluminum back boxes (no marking) may be assembled with XT suffix aluminum covers. XT suffix covers
can only be used with single gang back boxes and cannot be used with the GB suffix.
*Reducers required.
Crouse-Hinds series device covers UL/cUL Listed for use with EFS and EFSC Single Gang, EDS
and EDSC Single and Two Gang Device Bodies.
CLASS I, DIVISIONS 1 & 2, GROUPS B, C, D;
CLASS II, DIVISION 1, GROUPS E, F, G; DIVISION 2, GROUPS F, G; CLASS III WHEN USED WITH AN
EFS(C) BACK BOX.
DSD Covers
Pushbutton Covers
Catalog Nos. DSD918, -919, -920, -921, -922, -962, -970
Selector Switch Covers
Catalog Nos. DSD923, -924, -925, -926, -927
Pilot Light Covers
Catalog Nos. DSD947-†, DSD948-†-T2.
Pushbutton/Pilot Light Combination Cover
Catalog Nos. DSD958-†, DSD961-†
Blank Cover
Catalog No. DSD957
CLASS I, DIVISIONS 1 & 2, GROUPS C, D;
CLASS II, DIVISION 1, GROUPS E, F, G; DIVISION 2, GROUPS F, G; CLASS III WHEN USED WITH AN
EDS(C) BACK BOX.
DSD Covers
Pushbutton Covers
Catalog Nos. DSD918, -919, -920, -921, -922, -949, -950, -951, -962, -970
Selector Switch Covers
Catalog Nos. DSD923, -924, -925, -926, -927
Pilot Light Covers
Catalog Nos. DSD947-†, DSD948-†-T2.
Pushbutton/Pilot Light Combination Cover
Catalog Nos. DSD958-†, DSD961-†
Blank Cover
Catalog No. DSD957
Switch Covers
Catalog Nos. DSD933, -934, -936, -937
Catalog Nos. DSD935, -939, -940, -941
Manual Motor Controller Covers
Catalog Nos. DSD910, -911, -912, -913, -914, -915, -916, -917
†Add color symbol for each pilot light from table below
Color
Red
Green
Amber
Clear
Blue
CLASS I, DIVISIONS 1 & 2, GROUPS C, D
CPS Receptacle Covers
Catalog No. CPS152R for use with plugs. Catalog No. CPP516
CLASS I, DIVISIONS 1 & 2, GROUPS B, C, D;
CLASS II, DIVISIONS 1 & 2, GROUPS F, G; CLASS III
ENR Receptacle Covers
Catalog Nos. ENR5201, ENR6202 for use with plugs
Catalog Nos. ENP5151, -5201, -6152, -6202
Eaton's Crouse-Hinds Division
Copyright© 2016
Figure 2. EDS, EDSC, EFS and EFSC Dimensions
Symbol
J1
J3
J6
J10
J11
IF 328
IF 328
Revised 06/16
Supercedes 10/14

Publicité

loading

Sommaire des Matières pour Eaton EDS Serie

  • Page 1 All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not guaranteed. In accordance with Eaton’s Crouse-Hinds Division’s “Terms and Conditions of Sale,” and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.
  • Page 2 Conformément aux modalités et conditions de vente de Crouse-Hinds, les conditions d’utilisation n’étant pas de notre ressort, l’acheteur est tenu d’évaluer la pertinence de ce produit pour l’usage qu’il veut en faire et doit assumer les risques et responsabilités y afférents. Eaton’s Crouse-Hinds Division IF 328 1201 Wolf Street, Syracuse, NY 13208 • U.S.A. Révision 4...

Ce manuel est également adapté pour:

Efs serieEdsc serieEfsc serie