EZ205-ASI
P O W E R
C O M -E R R
A D R
A S- i
+
+
a Power
U
AS-Interface®
b COM-ERR
Connection to EZ7... or AS-Interface
master faulty
c ADR
Addressing socket AS-Interface
a Power
U
AS-Interface®
b COM-ERR
Conexión COM-ERR al EZ7... o perturbación
de AS-Interface
c ADR
Enchufe de direccionamiento AS-Interface
a Power
U
AS-Interface®
b COM-ERR
Erreur de communication avec EZ7...
ou module maître AS-Interface
c ADR
Prise d'adressage AS-Interface
a Power
U
AS-Interface®
b COM-ERR
Verbindung zu EZ7... oder AS-Interface
Master gestört
c ADR
Adressierbus AS-Interface
a Power
U
AS-Interface®
b COM-ERR
Collegamento con EZ7... oppure
AS-Interface
c ADR
Connettore per indirizzatore AS-Interface
IL05013005E
a
b
c
®
®
®
Master
®
®
®
®
Master disturbato
Installation Instructions
Instrucciones de montaje
Notice d'installation
Montageanweisung
Istruzioni per il montaggio
Electric current! Danger to life!
Only skilled or instructed persons may carry
out the following operations.
The power supply units are mounting devices.
The national regulations/specifications must be
observed for the installation of the devices.
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas. Las fuentes de
alimentación son aparatos de montaje. Para la
instalación de los aparatos han de tenerse en cuenta
las normativas/especificaciones a nivel local.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après. Les blocs d'alimentation
sont des appareils faisant partie intégrante d'une
installation. Veuillez respecter les normes de mise en
œuvre spécifiques aux différents pays.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkräfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Die Stromversorgungsgeräte sind Einbaugeräte.
Beachten Sie für die Installation der Geräte die
länderspezifischen Vorschriften.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate. Gli alimentatori
sono unità per montaggio interno. Per l'installazione
degli apparecchi è necessario rispettare le normative
specifiche di ciascun paese.
®
®
®
1/6

Publicité

loading

Sommaire des Matières pour Eaton EZ205-ASI

  • Page 1 Installation Instructions Instrucciones de montaje Notice d’installation Montageanweisung Istruzioni per il montaggio EZ205-ASI Electric current! Danger to life! Only skilled or instructed persons may carry out the following operations. The power supply units are mounting devices. The national regulations/specifications must be observed for the installation of the devices.
  • Page 2 Standard connection – Conexión estándar – Raccordement standard – Standardanschluss – Collegamento standard – – – – AS-i AS-i F 8 A – AS-Interface ® – – Addressing – Direccionamiento – Adressage – Adressierung – Indirizzamento ® AS-Interface Profil 7.F Slave –...
  • Page 3 Connection – Conexión – Raccordement – Anschluss – Collegamento ® AS-Interface EZ-LINK EZ205-ASI Fitting , removing Devices must be de-energized! Montaje , desmontaje ¡Los aparatos deben encontrarse libres de tensión! Montage , démontage Assurer la mise hors tension des appareils !
  • Page 4 AS-Interface EZ7... AS-Interface EZ7... AS-Interface Data exchange times – Frecuencia de cambio de datos – Durées d’échange de données – Datenaustauschzeiten – Frequenza scambio dati EZ205-ASI ® AS-Interface data is scanned once within one EZ cycle. EZ205-ASI ® EASY205-ASI Dentro de un ciclo EZ, los datos AS-Interface se analizan una vez.
  • Page 5 Fault detection EZ – Analyse d’erreurs EZ – Evaluation des erreurs EZ – Fehlerauswertung EZ – Segnale di anomalia EZ EZ7...-... EASY6...-... + 24 V EZ205-ASI EASY205-ASI ® ® a AS-Interface not connected or not ready a AS-Interface nicht angeschlossen oder nicht...
  • Page 6 AVERTISSEMENT : « RISQUE D’EXPLOSION. NE PAS DÉBRANCHER TANT QUE LE CIRCUIT EST SOUS TENSION, A MOINS QU’IL NE S’AGISSE D’UN EMPLACEMENT NON DANGEREUX » Eaton Electrical © 2005 by Eaton Corporation 1000 Cherrington Parkway All Right Reserved Moon Township, PA 15108...