THREE PHASE AND 3-1 PHASE WIRE DIAGRAMS

208 - 240V / 3Φ
BLACK
BLACK
PRIMARY
FUSES
120V SECONDARY
BLACK
WHITE
Element fuses provided when
amp draw exceeds 120A
1 Phase
RED
BLUE
YELLOW
BLACK
OR
3 Phase
RED
BLUE
YELLOW
BLACK
BLACK
BLACK
PRIMARY
FUSES
BLACK
WHITE
Element fuses provided when
amp draw exceeds 120A

WIRING DIAGRAMS

OPTIONAL
CONTACTOR 1
CONTACTOR 2
RED
BLUE
BLACK
J12
J13
CONTACTOR 1
CONTACTOR 2
COIL
COIL
120V
120V
RETURN
RETURN
BLACK
120:24
YELLOW
YELLOW
WHITE
BLACK
SECONDARY
FUSE
PILOT SWITCH
120VAC
120V RETURN
BLUE
ANODE
ANODE RETURN
GREEN
RED
LWCO
LWCO RETURN
GREEN
Figure 3. Three-Phase Wiring Diagram
OPTIONAL
CONTACTOR 1
CONTACTOR 2
J12
J13
CONTACTOR 2
CONTACTOR 1
COIL
120V
RETURN
BLACK
120:24
YELLOW
120V SECONDARY
YELLOW
WHITE
SECONDARY
BLACK
FUSE
PILOT SWITCH
120VAC
120V RETURN
BLUE
ANODE
GREEN
ANODE RETURN
RED
LWCO
LWCO RETURN
GREEN
Figure 4. 3-1 Phase Wire Diagram
CONTACTOR 3
CONTACTOR 4
J14
J15
CONTACTOR 3
CONTACTOR 4
COIL
COIL
120V
120V
RETURN
RETURN
OUT 3
OUT 4
J1-5
J1-4
J1-3
J1-1
J2
J3
J2-1
J5
J1
CONTROL
J7
JUMPERS
J2-3
BOARD
J9
AIN
J10
J11
DISPLAY
1
3
2
4
J12
J13
J14
J15
J16
J10-2
J10-1
Current Sensor Inputs
J10-4
J10-3
CONTACTOR 3
J14
J15
CONTACTOR 3
COIL
COIL
120V
120V
RETURN
RETURN
OUT 3
J1-5
J1-4
J1-3
J1-1
J2
J3
J2-1
J5
J1
CONTROL
J7
JUMPERS
J2-3
BOARD
J9
AIN
J10
J11
DISPLAY
1
3
2
4
J12
J13
J14
J15
J16
J10-2
J10-1
Current Sensor Inputs
J10-4
J10-3
13
CONTACTOR 5
J16
CONTACTOR 5
COIL
120V
RETURN
OUT 5
BLACK
J5-2
TEMPERATURE
J5-3
BLACK
J5-1
RED
ECO
J5-4
RED
DISPLAY
6
CAT5
J2-2
PROTECTIVE
EARTH
100295260
CONTACTOR 4
CONTACTOR 5
J16
CONTACTOR 4
CONTACTOR 5
COIL
COIL
120V
120V
RETURN
RETURN
OUT 4
OUT 5
BLACK
J5-2
TEMPERATURE
BLACK
J5-3
J5-1
RED
ECO
J5-4
RED
DISPLAY
6
CAT5
J2-2
PROTECTIVE
100295259
EARTH