Command 43 End defrosting temperature setting:
When the compressor pauses, the evaporator temperature is controlled by a probe. This command is used to
set the evaporator temperature beyond which the compressor can resume operation. The command is preset
at +8°C and can be modified between -15°C and +10°C.
Note: the temperature value setting can be increased or reduced by pressing button 3 or 6 on the external
selection push-button panel respectively.
Then set the parameter defined as the "dripping time". The value is preset at 240 secs. and can be modified
from 3 to 600 secs.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
Command 44 Sets defrost cycle frequency:
This command sets the interval between defrost cycles expressed in hours. This value can be varied from 1h
and 8h and is preset at 3h.
E
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
N
the same parameters for the SLAVE machine can be set.
G
Command 45 Setting the cut-out duration for the refrigeration safety device:
L
This command sets the amount of time that the refrigeration safety device is to remain disabled. This period
I
of time prevents the vending machine from shutting down following an operation that involves having the door
S
open with the subsequent increase in the internal temperature. The delay in activating the refrigeration unit
H
safety device gives the machine time to return to its normal operating temperature. The value of this
command is preset at 60 min. but can be varied from 30 to 360 min.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
This option is only available on FASTER SLAVE vending machines
Command 46 Setting the trigger temperature for the refrigeration safety device:
This command sets the trigger temperature for the safety device, that is the temperature above which it
prevents the machine from vending the selected product (see Command 48). A warning message appears
on the display when the user attempts to make one of these selections. This control is disabled when the
machine is switched on and after the door is shut for a period of time set on command 45. The preset value
is -5°C but it can be changed to between -8°C and +5°C. When the refrigeration unit safety device trips, the
selections involved remain out of service. To reset the refrigeration unit safety device: with the door open, the
event that occurred on the master vending machine or on the slave machines connected to it, appears on the
display of the master vending machine. Press ENTER on the external keypad to reset the device. If you press
the ESC button or close the door, the action remains active and is recorded as ERROR 93. If the refrigeration
unit safety device is still active when you close the door, an acoustic alarm (series of BEEPS) will
automatically begin to sound.
Note: the temperature value setting can be increased or reduced by pressing button 3 or 6 on the external
selection push-button panel respectively.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set. This option is only available on FASTER SLAVE
vending machines
Command 48 Setting trays with refrigeration safety device:
This command allows you to select which trays are subject to the refrigeration safety device. The command
requires a setting for each tray: enable safety device = 1, or disable safety device = 0. Tray 1 refers to the top
tray. By default, all the trays are set at 1.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
This option is only available on FASTER SLAVE vending machines
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
The products must be introduced at the correct temperature for preservation as specified by
the regulations in force. The non-observance of this regulation could activate the
"refrigeration safety device".
For detailed descriptions on the reloading modes, see paragraph "GUIDELINES FOR
LOADING PRODUCTS"