Humidity Control; Alarm Function - Lucky Reptile Humidity Control II Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Menü
Display
Function
Code
Hu1
Start Time Humidity Time Zone 1
F21
Humidity for Time Zone 1
Hu2
Start Time Humidity Time Zone 2
F22
Humidity for Time Zone 2
Hu3
Start Time Humidity Time Zone 3
F23
Humidity for Time Zone 3
Hu4
Start Time Humidity Time Zone 4
F24
Humidity for Time Zone 4
Timer Setting (switches coupling II, 8 functions menus total, F31 to F38, each must be programmed individually )
ONx
Timer On x (x = Function number, e.g F31 = On1)
F3x
Ofx
Timer Off x (x = Function number, e.g F31 = Of1)

Humidity Control:

Four humidity time zones (F21 to F24) can be programmed and are being activated over the time. This allows for a more natural simulation of the
daily humidity sequence without sudden humidity jumps. For each humidity time zone you set a humidity and the time from which on it is valid. You
can set the humidity individually as needed by your animals. Select the humidity time zone (F21 to F24) you want to edit. First set the time from which
on the humidity should be active and then enter the desired humidity. You can deactivate a humidity time zone, in case it is not needed. To do so, set
the time to 0F:00. Since you can deactivate every humidity time zone you can also operate the humidity control with a constant humidity value for
the whole day or with only two or three different humidity values over the day.
Humidifying/De-humidifying:
With F11 (Mod) the device can be switched between Humidifying and De-Humidifying Mode! In Humidifying mode the device will be operated until the
desired humidity is reached. Is the humidity dropping by more than the set hysterisis value in F12 (HYS) the humidity control activates the humidifier.
In De-Humidifying mode the attached device will be switched on as soon as the set humidity is surpassed by more than the value set in F12 (HYS).
As soon as the humidity drops below the set value, the attached de-humidifier is switched off. Use this mode for fans.

Alarm Function:

The alarm function F13 (ALr) allows to set a deviance where the device starts an alarm if the measured humidity is too high or too low by this value.
The deviation can be set from 0 to 50. Choosing 0 will shut off the alarm function. If the deviation is set to 5 and the desired humidity is 75%, the
alarm will start at 80% and below 70%. In case of alarm there is a warning sound and the display flashes.
The acoustic alarm can be switched off with function F14 (ALS) independently from the optical alarm. As a default the acoustic alarm is deactivated.
Timer:
The device has a real-time clock with timer. You can set 8 ON and 8 OFF times (in minutes) which will allow controlling devices, e.g. lighting plugged
into coupling II by time. Choose one of the available time slots (F31 to F38). Enter at on the desired starting time with the arrow keys. With SET you
can switch between hours and minutes and to the stop time oF. With ENT the settings are confirmed. The device always checks all timer settings for
the next logical switching time! E.g. if F31 is programmed from 8:00 to 13:00 but F32 to 9:00 to 10:00, then socket 2 will be switched off at 10:00 which
is the next logical switching time. Keep in mind that overlapping timer slots can cause undesired and most importantly different results depending
on the state of the controller. In case of a power loss, it could happen that timer slots become active as next logical step that are irrelevant in the
normal operation due to overlapping. We recommend a logical follow up programming where in F31 the earliest start time is set to allow for a better
overview. Set the respective menus (F31 to F38) to the desired time or to 0F:00 if you do not want to use the timer.
Display & MIN /MAX Function:
The display always shows the current humidity. If a red lamp is lighting above WORK the device is on. If a lamp is lighting above SET the device is
in settings mode.
With the arrow key up you can display the maximum measured humidity, with arrow key down the minimum measured humidity. The values are
reset every day at 00:01.
ENT will show the actual time. SET will show the currently valid humidity setting. All other settings can only be viewed in settings mode.
Possible
Settings
Humidity Settings (Coupling I is switched through these settings)
00:00 ~
00:00 ~23:59
00:00 ~23:59
00:00 ~23:59
00:00 ~23:59
00:00 ~23:59
Unit
Default
Setting
h:min
8:00
23:59
0 ~ 99
%
70
h:min
10:00
0 ~ 99
%
60
h:min
17:00
0 ~ 99
%
70
h:min
21:00
0 ~ 99
%
80
Hour:Minute
0F:00
Hour:Minute
0F:00
Comment
From this time on the humidity setting is valid
Switches coupling II
0F:00 = timer slot deactivated
2.

Publicité

Table des Matières
loading

Table des Matières