With the Humidity Control II you have purchased a digital humidity controlling device of the newest generation which can control all common
vivarium humidifiers with a maximum load of 1000W. The device has a realtime clock and four humidity time zones. For each humidity time zone a
different humidity value can be set allowing to recreate the natural humidity variations over the day inside the terrarium. An alarm function warns
optically and acoustically if the device measures a humidity that is either higher or lower than the set humidity. In addition the device has a timer
which allows you to time control additional devices like lighting or ventilators. The continuous humidity display and the small size of the humidity
control allow ita use as additional hygrometer.

Operating conditions

• The device may only be operated at 230V / 50/60Hz AC Voltage
• The device may be operated in any position, but it has to be ensured that it is impossible for it to fall into water.
• The ambient temperature limit during operation may not fall below and exceed 0°C and 60°C respectively.
• The device is designed for use in dry and clean rooms.
• At formation of condensed water a period of acclimatisation of up to 2h has to be ensured.
• Protect the device from moisture, spray water and impact of heat!
Designated Usage
In accordance with regulations the usage of this device is allowed with humidification systems for humidity control customary in trade in vacuum
containers (e. g. aquaria, terrariums) or rooms. Other forms of operation as mentioned above are not allowed.
Installation:
Install the humidity sensor at a suitable place inside the terrarium. In order to get correct measurement results the humidity sensor may not come
in direct contact with water mist.
Position the humidity control in way you can easily control the displayed humidity all the time. Plug in the devices you want to have controlled into
the receptacles of the device. Humidifiers in I and timer controlled devices (e.g. lighting) in II. Connect the AC Adaptor to properly installed socket.
You can now do the desired settings as to the following instructions.

Setting the Functions:

Press the SET button for more than 3 seconds to open the settings menu. There are 18 available menus from F00 to F38. For a clear overview the
settings have been arranged in groups. F00 to F14 are the global functions like clock, mode and alarm. F21 to F24 are the humidity time zones and
F31 to F38 the timer. Use the arrow buttons to choose between menus and press SET to enter the desired menu. You will see a shortname for each
function in the display, e.g. at F00 "ClC" for clock. Press any key to go ahead. With the arrow buttons you can change the settings. For changing time
settings you can switch from Minutes to Hours by Pressing SET. Press ENT to save settings and exit the menu. If you are finished with all settings
press ENT for more than 3 seconds to exit the settings menu. The device will start working with the new settings.
For details on the available functions please consult the chart below.
Menü
Display
Function
Code
F00
CLC
Clock
F11
MOD
Operation Mode
F12
HYS
Hysteresis (switching delay)
F13
ALR
Alarm Difference
F14
ALS
Acoustic Alarm On/Off
1.
Manual
Possible
Unit
Settings
General Settings
00:00 ~23:59
Hour:Minute
dH/Hu
1~50
%
0~50
%
ON/OFF
Default
Comment
Setting
Hu
Hu = add humidity, dH =de-humidifying
mode
15
Device warns when difference is bigger than
15
this value, 0= Alarm Off
OFF