7

INDOOR UNIT FIXING

1. Pass the pipe through the hole in the wall,
and hook the indoor unit on the installation
plate at the upper hooks.
2. Swing the indoor unit to right and left to
confirm that it is firmly hooked up on the
installation plate.
3. While pressing the indoor unit onto the
wall, hook it at the lower part on the
installation plate. Pull the indoor unit
toward you to confirm that it is firmly
hooked up on the installation plate.
1
2
Hook
• For detaching the indoor unit from the
installation plate, pull the indoor unit toward
you while pushing its bottom up at the specified
parts.
19-EN
Hook here
Installation plate
Press
(unhook)
Push
Push
8

DRAINAGE

1. Run the drain hose sloped downwards.
NOTE
• Hole should be made at a slight downward
slant on the outdoor side.
2. Put water in the drain pan and make sure
that the water is drained out of doors.
3. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with shield pipe.
Do not rise the drain hose.
2" (50 mm)
or more
Shield pipe
Inside the
Drain hose
room
Arrange the drain pipe for proper drainage from
the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed to
drain water collected from dew, which forms on
the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
Space for pipes
– 19 –
Installation Manual
Do not form the drain hose
into a wavy shape.
Do not put the
Do not put the
drain hose end
drain hose end
into water.
in the drainage
ditch.
Extension drain hose
CAUTION
Wall
Drain guide