Solenoid Leads
Keyed Switch (not used)
Hardwire Battery Clip
(Note: connection already
made to converter)
Sensor Lead
Fig. 8
STEP 4. CONTROLLER ADJUSTMENTS
If adjustments are required. Note factory defaults for program shown in Quick Reference Chart.
Otherwise, replace the driver board housing cover as the electronic product is ready for use.
Selection Adjustment
Run-On time
Response Time
Block Time
Sensor Range
Auto Timer
Metering Mode
060072A
Screws and
061210A
Driver Bit Kit
Sensor Plate
(Blue Ring)
Fig. 7
Hardwire Connection
060989A
Controller
(Controller is set to 10" range, metering mode
disabled - settings are adjustable)
Up and Down Arrow
3000T4328 CONTROLLER QUICK REFERENCE CHART
Description
The length of time water will run after
the user removes their hands from the
sensing zone.
Response Time is the amount of time it
takes for the sensor to react to hands
placed in the sensing zone.
The amount of time required between
uses. This prevents the faucet from
running water excessively.
You can set the distance at which the
sensor will detect hands in the wash area.
The auto timer is the length of time before
the faucet stops running in the event that
the sensor is obstructed by a foreign object.
Allows for continuous flow for a set amount
of time, regardless of how long an object
is placed in front of the sensor. Run-On
settings are disabled in this mode.
w w w . s p e c s e l e c t . c o m
57 mm (2.25")
MIN*
061264A
Spout Plate
060683A
Hardwire Converter
24VAC to 6VDC
Info Icon
LCD Display
Enter Exit Button
Factory Default Setting
0 Seconds
Standard (4 pulses/second)
1 second
8" (203 mm) from sensor
1 minute + Run-On time
10 seconds
Page 3
Controller Battery Clip
(Note: connection already made to controller)
Adjustment Range
0 to 8 seconds and
then 1 minute to 8
minutes
3 Settings:
Fast (8 pulses/second)
Standard (4 pulses/second)
Slow (2 pulses/second)
1 to 8 seconds of
blocking time
3" to 15" (76 mm to
381 mm) from sensor
Not Adjustable
7 to 240 seconds
(if enabled)
208782 Rev. A