Signalling
Occurs in case of intervention
of the auger duct temperature
safety thermostat.
AL 8
In the work phase the stove
SIC DEP
detects a pressure lower than
the vacuum switch threshold
setting .
Occurs when the stove has
SERVICE
exceeded the hours of
DUE
operation or 2000 Kg pellet
since the previous service
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
ALARMS - MESSAGES
Fault
-The safety thermostat has
detected a temperature above
the setting threshold due to
overheating of the bottom part
of the hopper, blocking
gearmotor operation.
- Overheating due to use of
the stove for too long
- Brazier clogged with
excessive accumulated ash.
- The combustion chamber is
dirty
- The fume duct is blocked
- The fire door is not closed
- The overpressure valves are
open-jammed
- The vacuum switch is faulty.
The stove requires
extraordinary maintenance
Possible causes
41
Cures
- Check the cleanness of the
fume duct and the combustion
chamber, hermetic closure of
the door and the overpressure
valve. Then repeat the lighting
procedure
Reset the safety thermostat by
pressing the reset button and
repeat the lighting procedure.
- Other reinstatement
operations must be carried out
by a service centre
The stove continues its normal
operation. It is advisable to
contact a service centre
as soon as possible
LIRA SLIM