4. Replace the cap after adjustment to lock the set-
ting. See Fig. 6.
Fig. 6. Lock the setting.

PARTS LIST

Model No.
UMV500-LF/U UnderSink Thermostatic Mixing Valve intended for use in under counter and
under sink applications for three port or four port applications. Four port
adapter included with UMV500-LF/U.
MAINTENANCE
Test the valve annually to make sure that the internal
parts operate properly.
1. Turn on the hot faucet and run water for a few
2. Remove the cap by pulling it off.
3. Use the cap upside down to adjust the outlet
4. Check the outlet water temperature with a ther-
5. When the correct outlet temperature has been
M36652
Description
3
minutes, until the hot inlet temperature is at its
maximum.
temperature with a thermometer under the fau-
cet. Turn the hand wheel one-half turn clockwise
for cooler temperatures and counterclockwise
for warmer temperatures.
mometer to make sure that the temperature
changed and the hand wheel turned without
binding.
reached, replace the cap to lock the setting.
UMV500 SERIES
Shipping
Weight lb (kg)
1.2 (0.55)
38-00056EFS—05