Design and Function

Attention!
Hazards must be ruled out before the moveable part of the
!
protection systems can be opened.
The key exchange unit is to be integrated into a system and connected
with a control unit so that the hazardous machine can run only when the
guard is locked and closed.
The second key can be removed after entering a first key. The first key is
blocked and the third key released after removing the second key. The first
key can only be removed again after the third and then the second key
were returned to their starting position.
Key exchange units are used in the system in connection with additional
STS units and SAFEMASTER products. The first key to be entered may
originate from these units (e.g. release through upstream solenoid locking
ZRH01A in connection with a speed monitor UH 5947 or standstill monitor
LH 5946). The second and further keys to be removed can serve as
protection against lock-in or for the operating release of additional units
(e.g. M10A, M11A, M12M, M10B01M).